Ask Hubble

Ask Hubble your question about the suite. Hubble searches the FAQ and answers in the bubble. All articles are listed below.

Hubble
Hey — I'm Hubble. Ask me anything about the suite. I search the help articles and show you the best matches.
Browse all help articles ↓

Quick access

Component
Classification

86 answers

Which sensors do I really need

Required inputs, useful additions, and what is missing without them – for Solar Forecast ML and Solar Forecast STATS.

In short

Solar Forecast ML needs three things: household consumption today in kWh, system capacity in kWp, and at least one panel group with a power sensor, azimuth, tilt, and kWp. Without these, there is no reliable forecast. Everything else is optional and improves the result: outdoor temperature, humidity, air pressure, wind, precipitation, solar irradiance, and illuminance. Enter the inverter AC limit when your system is curtailed – there is a separate article for that.

Solar Forecast STATS requires current household consumption in watts. Balances only start from that. Useful additions: battery state of charge in percent and battery power in watts, the energy flows solar to house, solar to battery, battery to house, grid to house, grid to battery, and house to grid, plus smart-meter import and export. The more flows you have, the more accurate autonomy, costs, and savings become.

Consumers such as a heat pump, heating rod, and wallbox are optional. They unlock the consumption atlas and the per-device view.

The sensor type matters: power is measured in watts and is an instantaneous value; energy is measured in kilowatt-hours and counts up. Where a field asks for watts, a kWh sensor must not be used – and the other way around.

What to check

  • Household consumption today in kWh is present and rises through the day
  • System capacity in kWp matches the module capacity, not the inverter capacity
  • Every panel group has a sensor, azimuth, tilt, and kWp
  • In STATS, household consumption in watts is assigned
  • Units checked: W for power, kWh for energy
Sensors and signalsIs SFML right for me?

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What happens in the first two weeks

When the forecast becomes usable, what applies until then, and how you can see the progress.

In short

Right after setup, SFML calculates from solar physics, your system data, and the weather. That is already a full forecast – it just does not know your system yet.

In the first days SFML collects measurements from your system and compares them with its own prediction. From that comparison it builds a picture of your roof: orientation in practice, recurring shade, and local weather habits. Forecast quality rises with the number of usable days, not with the number of calendar days – continuous poor weather makes it take longer.

Until enough suitable data is available, the forecast stays on the physical foundation. Messages such as ‘AI not trained’ are normal in this period and not a fault.

What you should avoid in this phase: swapping sensors, rebuilding panel groups, resetting the learning database. Each of those sets the learning progress back in whole or in part.

What to check

  • Watch forecast quality across several days instead of judging single days
  • No sensor or group changes in the early period
  • Exclude days with special events from learning instead of emptying the database
  • Keep an eye on the learning and quality sensors
What does AI not trained meanWhy is a new forecast still inaccurate

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What I should check after an update

Read the release notes, wait for the restart, then recheck the configuration – in that order.

In short

Read the release notes for the installed version first. They say whether an update changes settings, adds fields, or asks for a reconfiguration. Almost every problem after an update comes from skipping this step.

Restart Home Assistant fully once after the update, not only the integration. Then wait through one complete daily cycle before judging the forecast or the statistics: the morning routine runs once a day, and some views only fill in with the day’s hourly values.

Then check the settings the update mentions. After larger version jumps that is usually the panel groups, the sensor assignment, and the price thresholds. Existing values are not adjusted automatically when the meaning or unit of a field has changed.

If the interface still shows old content after the update, reload the page with a cleared browser cache. That affects the display, not the data.

What to check

  • Release notes of the installed version read
  • Home Assistant restarted fully
  • A full day waited before judging values
  • Panel groups, sensor assignment, and thresholds rechecked
  • Browser cache cleared if the page shows old values
Release notesCheck the version

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Who Solar Forecast ML is for

What your installation must provide and which knowledge you need — difficulty 2 out of 10.

In short

For a solar forecast you can drive automations with, SFML on its own is enough. You need the DC power sensor of the solar modules — the power arriving at the inverter, not the inverter output. With a battery, add a PV-to-battery sensor, and use a current version of Home Assistant.

The DC power value is the one hard condition. If your inverter does not provide it, there is no way around that.

What to check

  • DC power at the inverter, not the AC output
  • With a battery, a PV-to-battery sensor
  • A current version of Home Assistant
  • Your own system data: kWp, azimuth, tilt
Is SFML right for me?

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Who Solar Forecast STATS is for

Requires SFML and expects you to learn it — difficulty 6 out of 10.

In short

STATS is the full evaluation of your installation, extensive and deliberately not simplified. It requires a working SFML installation, a current household-consumption sensor, and suitable sensors for energy flows and consumers.

You need to assign energy flows, tell power from energy, and learn the figures. If you only want a forecast, you do not need STATS.

What to check

  • SFML is running
  • A current household-consumption sensor
  • Sensors for energy flows and consumers
  • Time to learn the evaluation
Is SFML right for me?

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Who Solar Forecast EAI is for

For a heat pump, storage, and a wallbox — requires SFML, STATS, and a licence, difficulty 8 out of 10.

In short

EAI is the most demanding component: local, explainable energy signals for a heat pump, storage, and a wallbox. SFML and STATS must be set up and stable, and you need a valid EAI licence.

EAI recommends and releases; it does not switch by itself. Switching is done only by your own Home Assistant automations.

What to check

  • SFML and STATS are stable
  • A valid EAI licence
  • A daily counter, not a lifetime counter used as today
  • Check signals before building automations on them
Is SFML right for me?

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Who Grid Price Monitor is for

Usable without SFML — difficulty 3 out of 10, closer to 5 out of 10 with battery functions.

In short

Grid Price Monitor is the accessible way in to dynamic electricity prices and runs without SFML as well. You need Home Assistant, a supported price source or a tariff you can represent, and you need to know your actual total price in ct/kWh.

The exchange price and the price you pay are not the same thing. Battery functions also need state of charge, capacity, limits, and a switching path you have tested — then the effort is closer to 5 out of 10.

What to check

  • A dynamic tariff or a supported price source
  • Total price in ct/kWh, not only the exchange price
  • For a battery: state of charge, capacity, and a tested switch
Is SFML right for me?

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Who Weather Fusion AI is for

Only useful with your own weather station — difficulty 3 out of 10.

In short

Without your own, correctly sited weather station at the location, WFAI makes no sense. A cloud weather entity or a remote station is not a substitute and must not be connected.

WFAI combines several weather sources with the readings from that station. Calibration takes patience. Recommended station: Ecowitt with the matching integration.

What to check

  • Your own weather station at the site, correctly installed
  • Measurements from the actual location
  • No cloud entity and no remote station as a substitute
Is SFML right for me?

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why is a STATS card empty or showing two dashes

Live cards require current sensor values; historical cards require stored hours or a completed day.

In short

An empty card or -- initially means that no suitable data foundation exists for that view. Live cards require valid current sensor readings. Daily, monthly, and quality cards require stored hours or at least one completed end-of-day run.

Optional areas only appear when their required sensors are configured with the correct measurement type. A battery card is deliberately absent without a valid SoC or power sensor. Investigation is warranted when the source is demonstrably current but the related STATS API remains empty after refresh.

What to check

  • Check system and database status in STATS
  • Check source sensor, unit, and timestamp
  • Wait for at least one end-of-day run for historical cards
  • Reload the page and inspect API status
  • Only map an optional sensor when its measurement and unit genuinely match
Check required sensors

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why do today's values keep changing

The current day remains provisional until every available hour is processed and end of day completes.

In short

Power, energy, costs, forecast comparison, and quality values for the current day grow with every new measurement. They may therefore change throughout the day. End of day creates the historical daily state.

Late readings or a controlled backfill can also complete a stored value. A historical day changing without a backfill, migration, or deliberate correction would require investigation.

What to check

  • Confirm whether the selected day is today
  • Check the latest sensor timestamp
  • Wait for end of day
  • Account for backfills, migrations, or corrections when historical values change

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why do P10, Morning Forecast, and Reforecast differ

The values serve different roles in the same forecast chain and do not have to match.

In short

Morning Forecast is the morning planning snapshot. A later Reforecast can include newer weather and system information. Morning Forecast, a later update, and the cautious planning value answer different questions and therefore do not have to match.

P10 is deliberately more conservative than the most likely forecast. It supports cautious planning and is neither an error nor a guaranteed lower bound. Historical hourly P10 values are not invented when they were not stored for a period.

What to check

  • Compare values for the same date and period
  • Do not confuse Morning Forecast with a later Reforecast
  • Do not compare daily kWh with current power
  • Do not interpret missing historical P10 hours as zero

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Read and use Hubble

What the reports contain, what “Ask Hubble” answers, and where the limits are.

In short

Hubble summarises what forecast, yield, consumption, battery, grid, prices, and weather mean together – as text, not as another row of numbers. Reports appear across the day, plus a short assessment of the current state.

The buttons give you specific answers: the current state, tips for the day, an assessment of forecast confidence, a look at the battery, the status of your sensors, and the memory. The memory compares today with similar days of your system and names the similarity, the yield then, and the most reliable time window.

Hubble recommends; it does not switch anything. The time windows are suggestions for flexible loads; you have to control them yourself or through your own automations.

How much Hubble can say depends on how complete your sensors are. If energy flows or battery values are missing, Hubble says less – sensor status shows what is missing. Without a licence you see Hubble with sample data.

What to check

  • Sensor status checked and missing values added
  • Time windows understood as a recommendation, not a switch command
  • With sample data: licence entered
Hubble energy copilot

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why do clean quality, total error, and percentages differ

The metrics use different data foundations and therefore answer different questions.

In short

Clean quality only evaluates hours accepted as reliable learning and comparison data. Total error can cover a broader period. Technically excluded hours are not ordinary model errors and must not distort the clean quality score.

MAE averages absolute errors, RMSE weights large deviations more heavily, and WAPE relates total error to actual production. In Modern, Bias is Forecast minus Actual, so a positive value means overforecasting. With very low actual production, a small absolute difference can create a large percentage error.

What to check

  • Check the evaluation foundation and time range
  • Read absolute kWh error alongside percentages
  • Consider learning basis, coverage, and excluded hours
  • Do not assume daily deviation and Bias use the same sign

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why does the energy balance not fully add up

Staggered sensor updates, missing directional flows, and rounding can create a visible balance gap.

In short

The Hubble daily balance compares household demand with known shares from direct solar, battery, and grid energy. Unassigned describes a positive gap whose source cannot be identified unambiguously from the configured sensors.

Momentary flows can briefly remain open because inverter, smart meter, and battery sensors do not update at exactly the same time. Persistent large deviations point to a wrong direction, duplicate mapping, unsuitable units, or a missing sensor.

What to check

  • Every flow sensor provides current power in W or kW
  • Import and export are separate positive directions
  • Exclude duplicate mapping of the same flow
  • Treat grid charging and battery discharge separately
  • Distinguish small timing or rounding differences from persistent gaps
Open sensor requirements

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why does Smart Charge only analyse instead of switching the battery

Without reliable SoC data and a verified grid-charging switch, Smart Charge deliberately remains an analysis.

In short

Smart Charge combines the GPM total electricity price, solar forecast, demand, losses, battery SoC, and configured SoC limits in STATS. A cheap price alone does not trigger charging. The decision also considers expected solar surplus and deliberately leaves battery capacity available.

For an actual switching action, smart_charging_switch must be a switch entity that reliably enables and disables grid charging at the inverter. battery_soc_sensor must provide a numeric value from 0 to 100 percent. Without the switch, the function remains analysis and recommendation; without reliable SoC data, no safe automatic decision can be expected. The tariff comes from GPM, not from a STATS price input sensor.

What to check

  • Manually test smart_charging_switch before enabling automation
  • battery_soc_sensor provides 0 to 100 percent
  • GPM provides total_price in ct/kWh
  • Check battery capacity and minimum and maximum SoC
  • Do not swap force-charge and normal price thresholds in GPM
  • Solar forecast and household demand are current
Check installation orderSet up Smart Charge

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why are tomorrow's electricity prices missing

Tomorrow's prices can remain absent until the selected provider publishes them.

In short

STATS and GPM can only show hourly prices already provided by the selected source. An incomplete tomorrow series is normal before publication and is not filled with invented values.

Investigation is warranted when the source demonstrably provides complete prices but STATS or GPM still does not import them after refresh. The value must be classified as a total price in ct/kWh; an exchange price does not automatically include network fees, taxes, and surcharges.

What to check

  • Wait for the provider's publication time
  • Check the GPM or aWATTar source
  • Check timestamp and time zone
  • Reload after publication
  • Do not confuse total price and exchange price

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why does Modern show stale values or offline status

Modern keeps the last loaded values visible and marks them stale or offline when current responses are missing.

In short

Modern does not immediately remove the last known value when an update fails. It keeps the value visible for context and marks it stale or offline. This is more useful than an invented zero, but the timestamp must be considered.

After a backend update, restart Home Assistant or the integration as instructed. If only the browser remains outdated, perform a hard refresh. Also verify ui_mode=modern and that backend, API, and frontend originate from the same build.

What to check

  • Check the displayed timestamp
  • Perform a browser hard refresh
  • Restart Home Assistant after a backend update
  • Check ui_mode=modern
  • Compare API and system status

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why are forecast quality or individual Modern analyses missing

Some Modern analyses only appear after their minimum data foundation has been reached.

In short

Forecast Health requires at least seven valid days in the 14-day window. Model Battle compares common valid model hours and requires at least 24 hours from three days. Comparable Days requires at least 14 qualified candidates.

Weather Impact requires at least 30 suitable points from three days. Solar Conditions requires at least eight daylight hours and 70 percent weather coverage. Until these thresholds are reached, the reduced or empty state is intentional and prevents conclusions from an insufficient foundation.

What to check

  • Check the number of valid days and hours
  • Check measurement and weather coverage
  • Consider exclusions and data gaps
  • Continue running with stable sensors
  • Do not fill missing history with manual zeros

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why is the shadow fingerprint empty

An empty or incomplete fingerprint does not prove a failure: shading only appears when the local patterns are sufficiently reliable.

In short

A general failure of shadow detection cannot be inferred from an empty fingerprint. The complete chain works on the verified reference installation: shadow model version 2.0 is ready, 2,434 seasonal system observations and five qualified system patterns are available, groups 3 and 4 also contain qualified patterns, and the API returns the heatmap data correctly.

The fingerprint deliberately does not show every physical shade event. A result only appears when the model can reliably distinguish reduced output from clouds, low sun, snow, and unknown causes. A deviation from the physical reference alone is therefore not evidence of building or tree shade.

A current hourly pattern requires a completed end-of-day learning run, at least seven observations, and at least 50 percent confidence. A seasonal month-hour pattern requires at least three observations. The local cause must be building_tree_obstruction or possible_obstruction; the 30-day model additionally requires at least 60 percent local-cause probability.

Without a radiation or lux sensor, the sensorless path is deliberately stricter: it accepts only clear weather and at least 30 percent local underperformance. Partial shading of individual modules can remain below this threshold in the overall system and is then intentionally not reported as confirmed shade. After the database has been deleted, the model must rebuild the required history from scratch.

What to check

  • Confirm that the end-of-day learning run completed
  • Check for at least 7 observations for the current hourly pattern
  • Check for at least 3 seasonal observations for the month and hour
  • Confirm at least 50% confidence
  • Check for local cause building_tree_obstruction or possible_obstruction
  • For the 30-day model, confirm at least 60% local-cause probability
  • Without a radiation or lux sensor, check for clear weather and at least 30% local underperformance
  • Consider clouds, low sun, snow, MPPT events, and learning exclusions
  • After deleting the database, allow enough new history to accumulate

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why are older data or the first days missing

STATS starts with actual collection and does not reconstruct missing history with invented values.

In short

Live values can appear immediately, while historical analyses require stored hours or completed days. Weather history, Consumer Atlas, and quality views therefore begin with the data that genuinely exists.

A lifetime cumulative sensor does not replace missing hourly history. When backfill is deliberately disabled or unavailable, the older period remains empty. This is correct as long as new live samples and daily closures are stored continuously.

What to check

  • Determine when STATS first started collecting
  • Wait for at least one end-of-day run
  • Confirm that new live samples are stored
  • Do not interpret missing as zero
  • Do not map unsuitable lifetime totals as historical substitutes

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What is the difference between self-sufficiency and self-consumption

Self-sufficiency looks at household demand; self-consumption looks at how generated solar energy is used.

In short

Self-sufficiency describes the share of household demand covered without direct grid import. Self-consumption describes the share of generated solar energy used within the local system instead of being exported. The two values can therefore differ substantially.

Grid charging of the battery must be reflected in source attribution and must not artificially increase solar self-sufficiency. Incomplete directional flow sensors can reduce both metrics or leave a share unassigned.

What to check

  • Consider household demand and solar production separately
  • Account for battery grid charging
  • Map import, export, and battery flows correctly
  • Check unassigned energy in the daily balance

✓Technically reviewed: SFML · STATS · EAI V52.0.4

How do I get the EAI license key and where do I enter it

One-time contribution in the Ko-fi shop, code by email, enter it only in Solar Forecast EAI.

In short

Premium features need a lifetime EAI license key.

Get the code from the Ko-fi shop (no subscription): https://ko-fi.com/s/8bc3808d22 — the voluntary contribution is currently €15. After purchase the license code arrives by email; also check spam and junk. No registration is required.

Enter the code only in the Solar Forecast EAI integration — not in SFML and not in STATS. Full premium scope needs EAI and GPM installed.

If the license warning stays after you entered a code: confirm you saved it in EAI, that the code is complete with no leading or trailing spaces, and restart Home Assistant fully once. The “heat-pump intelligence” checkbox is not a substitute for the license key; without a valid key, premium stays locked.

If no email with the code arrives, write to info@solarforecastml.com so delivery can be followed up.

What to check

  • Purchase completed in the Ko-fi shop and spam/junk checked
  • Code entered only in Solar Forecast EAI
  • EAI and GPM installed
  • Home Assistant restarted after saving
  • No spaces before or after the code
Ko-fi Shop EAI PremiumInstallation

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What is MDC / Midday Correction

MDC is Adaptive Forecast: an optional early-afternoon check, not a forced rewrite.

In short

MDC means Midday Correction — in the UI the option is called Adaptive Forecast. Early in the afternoon it compares the morning forecast with actual production so far.

If they diverge clearly, SFML uses fresh weather data and further criteria to decide whether correcting the afternoon forecast is useful. The switch allows that automatic correction; it does not force it. Default is OFF.

A large deviation alone therefore does not guarantee a correction. The morning forecast stays the morning planning baseline; a later reforecast or an MDC correction answers a different question and need not show the same kWh value.

Turn Adaptive Forecast on only if you really want automatic afternoon corrections. Then watch several days instead of judging from a single afternoon.

What to check

  • Adaptive Forecast set intentionally (default OFF)
  • Do not confuse morning forecast with a later reforecast or MDC
  • Judge deviation across several days
  • Check afternoon weather data and sensor freshness

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What does SMC mean

SMC is Smart Charge: GPM supplies prices, STATS decides and switches grid charging.

In short

SMC means Smart Charge (also Smart Charging). It needs Grid Price Monitor and Solar Forecast STATS.

GPM knows the prices and which hours are cheap. STATS knows battery state of charge, consumption and the solar forecast from Solar Forecast ML, makes the charge decision and switches. If GPM price signals are missing, STATS turns grid charging off.

A cheap price alone does not start charging. Without a reliable SoC and a proven grid-charge switch, Smart Charge stays analysis only on purpose.

One-time setup is under Settings › Solar Forecast Stats › Configure › Battery. Details are in the Smart Charge setup article.

What to check

  • GPM and STATS installed
  • GPM supplies total_price in ct/kWh
  • SoC readable as 0–100 %
  • Charge switch is domain switch and manually tested
Smart Charge setupWhy Smart Charge only analyses

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why do *_today sensors briefly show negative values at midnight

Just after midnight the recorder can show a transition value; the daily counter should restart near zero.

In short

Sensors named *_today count energy since midnight. At the day change Home Assistant resets the counter. In the recorder a short negative or jumpy value can appear while old and new values overlap.

That is usually a display transition, not proof of negative production. What matters is whether the sensor then restarts near zero and rises plausibly through the day.

Action is needed if the daily counter stays negative, never resets, or keeps climbing like a lifetime total. Then the entity is unsuitable for a “today” field.

What to check

  • Recheck the value after 00:05
  • Daily counter starts near zero and rises during the day
  • No lifetime cumulative total used as *_today
  • Unit is Wh or kWh, not W

✓Technically reviewed: SFML · STATS · EAI V52.0.4

When does the fog notification fire

The message reports a detected fog state; you can disable the notification in advanced options without stopping detection.

In short

The fog notification is one of the weather-state messages in SFML advanced options. It reports that SFML detected fog — not that the forecast is broken.

If you turn the notification off, SFML only suppresses that message. Detection and forecasting stay active.

Judge it together with the timestamp and weather and production sensors. A single message without a lasting deviation is no reason to reset the learning database.

What to check

  • Advanced options: fog notification checked
  • Compare message time with weather and production values
  • Do not confuse the notification with a forecast fault
  • Keep only notifications that help day to day

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why the STATS dashboard will not load

Check URL, browser cache and access path first — often display, not broken statistics.

In short

If the STATS dashboard stays blank or will not load, separate display from data. Statistics can keep running while the browser, URL or remote access blocks the UI.

Check the STATS URL, hard-refresh the page (clear cache) and try a second browser. Firefox and Nabu Casa remote access show display issues more often than local LAN access.

After a backend update, fully restart Home Assistant and reload the page. If Modern marks values stale or offline, the last known value stays visible on purpose — not an invented zero.

If only the UI is dead while SFML and STATS sensors show fresh values in Developer Tools, the fault is frontend or access path, not automatically the forecast.

What to check

  • STATS URL and ui_mode checked
  • Hard refresh / second browser tested
  • Local vs Nabu Casa remote access compared
  • Home Assistant restarted after update
  • Sensor values current in Developer Tools

✓Technically reviewed: SFML · STATS · EAI V52.0.4

How do I follow learning progress without a DEV token

Public quality and status sensors are enough; internal DEV logs are not an end-user tool.

In short

Learning progress lives in the integration’s status and quality sensors — not in a separate DEV token or internal log access. Messages such as “AI not trained” or a Pending Candidate state the situation in plain language.

Watch forecast quality and learning status across several suitable days. Quality rises with usable learning days, not calendar days. Individual excluded hours often protect the model on purpose.

Internal developer paths and protected logs cannot be reliably interpreted from outside. Use the help for setup and understanding; reproducible faults belong in the bug tracker with version and screenshot — not as free-form log interpretation.

What to check

  • Learning and quality sensors visible in Home Assistant
  • Judge status across several days, not one hour
  • Read “AI not trained” and Pending Candidate in the help
  • Do not share credentials or full raw logs publicly
What AI not trained means

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Which sensors are required, optional, or provided

In short: inputs are what you give an integration (required, optional, or for a feature); outputs are what it provides to you. 83 inputs and 178 outputs are documented.

In short

Hubble separates two directions. Inputs (input sensors) are chosen in the config flow: required means the integration will not start without it; “at least one” means one of the group is enough; “for feature” means only needed when you enable that feature; optional improves results. Provided outputs are sensors and entities the integration creates in Home Assistant itself – standard, optional, or when configured.

SFML: Actual PV power is the mandatory basis; consumption, weather, and battery values extend the local system model. Required: Current PV power per panel group (power_sensor).

STATS: One home-power sensor is enough to start. Directional flows and detailed values refine the balance. Smart Charge and tariffs are separate: SoC and charge switch in STATS, prices in GPM. Required: Current home consumption (sensor_home_consumption).

GPM: Price functionality starts without sensors. A battery power sensor is needed only for charge history. Required: no sensor mapping.

WFAI: At least one local weather measurement connects forecasts to the actual microclimate at the site. Required: Outdoor temperature (temperature_sensor), Humidity (humidity_sensor), Air pressure (pressure_sensor), Wind speed (wind_speed_sensor), Wind direction (wind_direction_sensor), Precipitation (rain_sensor).

EAI: Three heat-pump values form the mandatory basis; operating, thermal, and wallbox data are added by feature. Required: Current heat-pump power (heat_pump_power_sensor), Heat-pump energy today (heat_pump_energy_today_sensor), Outdoor temperature (outdoor_temperature_sensor).

TFS: No separate sensor mapping: Toorox ForeSight HA works directly with the local SFML database. Required: SFML installation and local database (sfml_database).

Tip: just ask me about a sensor – its name or technical key such as total_price or power_sensor is enough.

What to check

  • Required sensors mapped for each integration
  • Unit matches (W/kW for power, kWh for energy)
  • Feature sensors only needed when the feature is enabled
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Which input sensors does SFML (Solar Forecast ML) need

Actual PV power is the mandatory basis; consumption, weather, and battery values extend the local system model.

In short

Actual PV power is the mandatory basis; consumption, weather, and battery values extend the local system model. Base installation: This input represents real PV production and is the learning basis for SFML. Consumption & local weather: Optional local measurements extend the system context. SFML reads their numeric values without unit conversion. Battery and curtailment detection: Only required when optional battery/MPPT detection is used.

Current PV power per panel group (power_sensor, W · kW) – required. Numeric current active power. Each configured panel group needs its own sensor. Connects forecast, geometry, and actual production for the local system model. The config flow validates a numeric value and W or kW. At least panel group 1 is required.

Home consumption today (total_consumption_today, kWh) – optional. Cumulative total consumption since midnight; resets to 0 daily. Enables consumption statistics in the local system model. The code reads the numeric value directly as kWh and does not validate the unit.

Local outdoor temperature (temp_sensor, °C) – optional. Numeric local outdoor temperature. Frost, snow, and weather context. The numeric value is stored as °C without conversion.

Local humidity (humidity_sensor, %) – optional. Numeric relative humidity. Local humidity, fog, and weather context. The numeric value is used without unit conversion.

Local pressure (pressure_sensor, hPa) – optional. Numeric air pressure. Extends local weather context. The numeric value is stored as hPa without conversion.

Local wind speed (wind_sensor, m/s) – optional. Numeric wind speed in metres per second. Extends weather and system context. The code labels and stores the numeric value as m/s; km/h is not converted.

Local precipitation (rain_sensor, mm/h) – optional. Numeric current precipitation value. Supports rain, snow, and weather assessment. The numeric value is read directly; the config flow does not validate its unit.

Solar irradiance (solar_radiation_sensor, W/m²) – optional. Numeric global irradiance on the measurement surface. Improves cloud and irradiance context. The numeric value is used as W/m² without conversion.

Illuminance (lux_sensor, lx) – optional. Numeric illuminance from an outdoor sensor. Additional local brightness and cloud indicator. The numeric value is used as lux without conversion.

PV power to battery (solar_to_battery_sensor, W) – needed only for the related feature. Positive current power flowing from PV into the battery. Helps distinguish curtailment from low battery charging. The code reads the value directly as W; kW is not converted.

What to check

  • Current PV power per panel group: W · kW
  • Map optional sensors only with a matching unit
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Which input sensors does STATS (Solar Forecast STATS) need

One home-power sensor is enough to start. Directional flows and detailed values refine the balance. Smart Charge and tariffs are separate: SoC and charge switch in STATS, prices in GPM.

In short

One home-power sensor is enough to start. Directional flows and detailed values refine the balance. Smart Charge and tariffs are separate: SoC and charge switch in STATS, prices in GPM. Base installation: Current home consumption is the only mandatory sensor mapping. Directional energy flows: Optional positive power sensors for accurate source and flow accounting. Battery & fallbacks: Additional values for battery analysis and grid accounting. From V46.2.0, electricity tariffs are configured only in GPM. Smart Charge: From V46.2.0, Smart Charge lives in STATS. Prices come from GPM; the charge switch remains a separate Home Assistant entity. Consumers & detailed data: Optional mappings for the consumer atlas, heat pump, and wallbox.

Current home consumption (sensor_home_consumption, W · kW) – required. Current total household power demand. STATS integrates daily consumption from midnight. The config flow filters power sensors; kW is converted to W internally.

Weather entity (weather_entity, weather.*) – optional. Home Assistant weather entity with current condition and forecast attributes. Adds weather context to the analysis. The config flow only accepts the weather domain.

PV → home (sensor_solar_to_house, W · kW) – optional. Current positive power for this flow direction. Separates direct solar use from other household demand. Numeric values are read; kW is converted to W internally.

Inverter AC output (sensor_inverter_ac_output, W · kW) – optional. Current positive power for this flow direction. Captures total inverter AC output. Numeric values are read; kW is converted to W internally.

PV → battery (sensor_solar_to_battery, W · kW) – optional. Current positive power for this flow direction. Accounts for direct battery charging from solar. Numeric values are read; kW is converted to W internally.

Battery → home (sensor_battery_to_house, W · kW) – optional. Current positive power for this flow direction. Accounts for battery supply to the home. Numeric values are read; kW is converted to W internally.

Grid → home (sensor_grid_to_house, W · kW) – optional. Current positive power for this flow direction. Accounts for direct household grid import. Numeric values are read; kW is converted to W internally.

Grid → battery (sensor_grid_to_battery, W · kW) – optional. Current positive power for this flow direction. Accounts for battery charging from the grid. Numeric values are read; kW is converted to W internally.

Home/PV → grid (sensor_house_to_grid, W · kW) – optional. Current positive power for this flow direction. Accounts for export to the grid. Numeric values are read; kW is converted to W internally.

Smart meter grid import (sensor_smartmeter_import, W · kW) – optional. Current positive power for this flow direction. Provides grid import measurement or reconciliation. Numeric values are read; kW is converted to W internally.

Smart meter grid export (sensor_smartmeter_export, W · kW) – optional. Current positive power for this flow direction. Provides grid export measurement or reconciliation. Numeric values are read; kW is converted to W internally.

Battery state of charge (sensor_battery_soc, %) – optional. Numeric current state of charge. Shows state of charge and supports battery analysis. The config flow filters sensors with the battery device class.

Bidirectional battery power (sensor_battery_power, W · kW) – optional. Positive while charging, negative while discharging. Can supplement or replace directional battery flows. Numeric values are read; kW is converted to W internally.

Grid import today (sensor_grid_import_extra, kWh) – optional. Cumulative grid import since midnight. Fallback for daily grid import accounting. The config flow filters energy sensors; a daily-reset kWh value is expected.

Battery state of charge for Smart Charge (battery_soc_sensor, %) – needed only for the related feature. Numeric state of charge between 0 and 100. Compares current SoC with target, minimum, and maximum SoC. Runtime logic rejects values outside 0–100.

Grid-charge switch (smart_charging_switch, switch.*) – needed only for the related feature. Switch entity that enables and disables grid charging at the inverter. Performs the Smart Charge decision as a switching action. Without the switch, the function remains analysis. The config flow accepts switch entities.

Heat-pump power (sensor_heatpump_power, W · kW) – optional. Current electrical power draw. Classifies the heat pump as a major consumer. kW is converted to W internally.

Heating-rod power (sensor_heatingrod_power, W · kW) – optional. Current electrical power draw of the heating rod. Separates heating-rod consumption from the heat pump. kW is converted to W internally.

Wallbox power (sensor_wallbox_power, W · kW) – optional. Current wallbox charging power. Classifies EV charging as a major consumer. kW is converted to W internally.

Wallbox status (sensor_wallbox_state, Text) – optional. Stable text state for charging or connection status. Adds operating state to power readings. The code reads the entity state as text.

Heat-pump heating mode (sensor_hp_heating_mode, select) – optional. Current selected heating mode. Attributes runtime to space heating. The config flow accepts select entities.

Heat-pump hot-water mode (sensor_hp_dhw_mode, select) – optional. Current selected hot-water mode. Attributes runtime to hot-water production. The config flow accepts select entities.

Hot-water charging active (sensor_hp_dhw_charging, binary_sensor) – optional. Binary on/off state. Marks active hot-water production. The config flow accepts binary sensors.

PV operation active (sensor_hp_pv_active, binary_sensor) – optional. Binary on/off state. Marks PV-optimised heat-pump operation. The config flow accepts binary sensors.

Heat-pump electrical power (sensor_hp_electric_power, W · kW) – optional. Current electrical input power. Basis for efficiency metrics. kW is converted to W internally.

Heat-pump thermal power (sensor_hp_thermal_power, W · kW) – optional. Current delivered thermal power. Compares electrical and thermal power. kW is converted to W internally.

Heat-pump grid energy today (sensor_hp_grid_energy_daily, kWh) – optional. Cumulative grid energy since midnight. Separates paid heat-pump energy. A daily-reset energy counter is expected.

Heat-pump PV energy today (sensor_hp_pv_energy_daily, kWh) – optional. Cumulative PV share since midnight. Separates solar heat-pump energy. A daily-reset energy counter is expected.

Heat-pump seasonal performance factor (sensor_hp_jaz, Zahl) – optional. Numeric efficiency ratio. Shows the ratio of heat output to electricity input. The numeric value is read as a dimensionless ratio.

Compressor starts (sensor_hp_compressor_starts, Anzahl) – optional. Monotonic or clearly scoped counter value. Evaluates cycling and system load. The code expects a numeric counter.

Storage temperature (sensor_hp_storage_temp, °C) – optional. Current storage temperature. Adds heat-pump and storage analysis. The config flow filters temperature sensors.

Wallbox charging mode (sensor_wb_charge_mode, select) – optional. Current selected charging mode. Attributes charging sessions to the selected mode. The config flow accepts select entities.

Wallbox session energy (sensor_wb_energy_session, kWh) – optional. Cumulative energy for the current charging session. Evaluates individual charging sessions. The config flow filters energy sensors.

What to check

  • Current home consumption: W · kW
  • Map optional sensors only with a matching unit
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Which input sensors does GPM (Grid Price Monitor) need

Price functionality starts without sensors. A battery power sensor is needed only for charge history.

In short

Price functionality starts without sensors. A battery power sensor is needed only for charge history. Important: The battery power sensor must currently provide watts. Runtime does not convert kW. Smart Charge lives in STATS. Base installation: Price monitoring requires no sensor mapping. Tariffs, thresholds, and community CSV corrections are configured in GPM. Battery charge history: Only this sensor is needed for optional charge history. Smart Charge and SoC live in STATS.

Battery grid-charging power (battery_power_sensor, W) – needed only for the related feature. Positive current charging power. Negative values are treated as 0. Integrates charged energy for day, week, and month. The code reads the numeric value directly as W. kW is currently not converted.

What to check

  • Map optional sensors only with a matching unit
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Which input sensors does WFAI (Weather Fusion AI) need

At least one local weather measurement connects forecasts to the actual microclimate at the site.

In short

At least one local weather measurement connects forecasts to the actual microclimate at the site. Local weather basis: At least one of the six sensors is required. More local measurements improve the fusion basis.

Outdoor temperature (temperature_sensor, °C) – required – at least one of the group. Numeric local outdoor temperature. Local reference for temperature forecasts. The numeric value is used without temperature conversion.

Humidity (humidity_sensor, %) – required – at least one of the group. Numeric relative humidity. Local reference for humidity forecasts. The numeric value is used without unit conversion.

Air pressure (pressure_sensor, hPa) – required – at least one of the group. Numeric local air pressure. Local reference for pressure forecasts. The numeric value is used without pressure conversion.

Wind speed (wind_speed_sensor, km/h · m/s · mph · kn · ft/s) – required – at least one of the group. Numeric local wind speed. Local reference for wind forecasts. m/s, mph, kn, and ft/s are converted to km/h internally.

Wind direction (wind_direction_sensor, 0–359°) – required – at least one of the group. Numeric wind direction; values are normalised to a full circle. Adds direction and local wind dynamics. The code normalises the numeric value modulo 360. The German config-flow description is currently missing.

Precipitation (rain_sensor, mm/h · mm · in/h · in) – required – at least one of the group. Either a current rate or a monotonic precipitation counter. Local reference for precipitation forecasts. Inch values are converted to millimetres; total_increasing with mm is recognised as a counter.

What to check

  • Outdoor temperature: °C
  • Humidity: %
  • Air pressure: hPa
  • Wind speed: km/h · m/s · mph · kn · ft/s
  • Wind direction: 0–359°
  • Precipitation: mm/h · mm · in/h · in
  • Map optional sensors only with a matching unit
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Which input sensors does EAI (Solar Forecast EAI) need

Three heat-pump values form the mandatory basis; operating, thermal, and wallbox data are added by feature.

In short

Three heat-pump values form the mandatory basis; operating, thermal, and wallbox data are added by feature. Heat-pump base installation: These three measurements are required for heat-pump analysis. Operation & efficiency: Optional operating values improve explainability and accuracy of heat-pump assessment. Thermal & advanced analysis: Optional measurements for thermal efficiency, storage, and circulation losses. Wallbox optimisation: Only required when wallbox functionality is enabled. Exactly one demand input is added depending on the selected demand mode.

Current heat-pump power (heat_pump_power_sensor, W · kW · MW) – required. Current electrical power draw. Detects operation, load, and energy demand. The config flow validates the power unit; runtime converts to W.

Heat-pump energy today (heat_pump_energy_today_sensor, Wh · kWh · MWh) – required. Cumulative electrical energy consumption since midnight. Provides daily consumption and the learning target. The config flow validates the energy unit; runtime converts to kWh.

Outdoor temperature (outdoor_temperature_sensor, °C · °F) – required. Current numeric outdoor temperature. Relates heat demand and system behaviour to weather. The config flow accepts Celsius and Fahrenheit; runtime normalises temperature.

Indoor temperature (indoor_temperature_sensor, °C · °F) – optional. Current indoor temperature. Assesses comfort and thermal response. Temperature values are normalised.

Target temperature (target_temperature_sensor, °C · °F) – optional. Current target temperature. Explains load changes caused by target settings. Temperature values are normalised.

Operating mode (operation_mode_sensor, Text) – optional. Stable text state such as heating, hot water, or off. Attributes consumption to operating mode. The code reads the state as text; stable state names are required.

Compressor status (compressor_sensor, Ein/Aus · 0/1) – optional. Binary, switch, or numeric operating state. Detects actual compressor runtime. Several state formats are normalised to active/inactive.

Heating-element status (heating_element_sensor, Ein/Aus · 0/1) – optional. Binary, switch, or numeric operating state. Detects direct electric auxiliary consumption. Several state formats are normalised to active/inactive.

Hot-water temperature (dhw_temperature_sensor, °C · °F) – optional. Current tank temperature. Assesses hot-water demand and storage state. Temperature values are normalised.

Flow temperature (flow_temperature_sensor, °C · °F) – optional. Current flow temperature. Assesses heat delivery and system load. Temperature values are normalised.

Return temperature (return_temperature_sensor, °C · °F) – optional. Current return temperature. Enables temperature spread and efficiency assessment. Temperature values are normalised.

Compressor starts (compressor_starts_sensor, Anzahl) – optional. Numeric counter with a clearly defined scope. Assesses cycling and wear indicators. The code expects a numeric counter; its scope must match the description.

Total runtime (runtime_sensor, h) – optional. Cumulative runtime counter. Assesses usage and long-term efficiency. The code expects a numeric hour value.

Heating runtime (runtime_heating_sensor, h) – optional. Cumulative runtime counter for space heating. Separates space-heating from hot-water operation. The code expects a numeric hour value.

Hot-water runtime (runtime_dhw_sensor, h) – optional. Cumulative runtime counter for hot water. Separates hot-water from space-heating operation. The code expects a numeric hour value.

Heating-element power (heating_element_power_sensor, W · kW · MW) – optional. Current electrical heating-element power. Quantifies auxiliary heating and cost. Power values are normalised to W.

Heating-element energy today (heating_element_energy_today_sensor, Wh · kWh · MWh) – optional. Cumulative energy consumption since midnight. Accounts for daily auxiliary consumption. Energy values are normalised to kWh.

Thermal energy (thermal_energy_sensor, Wh · kWh · MWh) – optional. Cumulative generated heat energy. Calculates actual thermal efficiency. Energy values are normalised to kWh.

SPF/COP metric (jaz_sensor, Zahl) – optional. Numeric dimensionless efficiency ratio. Adds to calculated efficiency assessment. The code expects a numeric ratio.

Volume flow (volume_flow_sensor, l/min · m³/h) – optional. Current heating-circuit volume flow. Supports thermal power calculation. The code expects numeric volume flow; unit and scale must match the source.

Source temperature (source_temperature_sensor, °C · °F) – optional. Current heat-source temperature. Explains heat-pump efficiency changes. Temperature values are normalised.

Storage temperature (storage_temperature_sensor, °C · °F) – optional. Current thermal-storage temperature. Models storage state and losses. Temperature values are normalised.

Storage ambient temperature (storage_ambient_temperature_sensor, °C · °F) – optional. Current ambient temperature around the storage tank. Determines temperature-dependent standby losses. Temperature values are normalised.

Circulation pump (circulation_pump_sensor, Ein/Aus · 0/1) – optional. Binary, switch, or numeric operating state. Attributes circulation losses to active runtime. Several state formats are normalised to active/inactive.

Circulation return temperature (circulation_return_temperature_sensor, °C · °F) – optional. Current circulation return temperature. Supports assessment of circulation losses. Temperature values are normalised.

Current wallbox power (wallbox_power_sensor, W · kW · MW) – needed only for the related feature. Current electrical charging power. Detects active EV charging and energy demand. Mandatory when wallbox is enabled; power values are normalised to W.

Wallbox energy today (wallbox_energy_today_sensor, Wh · kWh · MWh) – optional. Cumulative charging energy since midnight. Accounts for daily EV consumption. Energy values are normalised to kWh.

Vehicle connected (wallbox_connected_sensor, Ein/Aus) – optional. Binary connection state. Prevents recommendations when no vehicle is connected. States are normalised to connected/not connected.

Vehicle charging (wallbox_charging_sensor, Ein/Aus) – optional. Binary charging state. Distinguishes connection from active charging. States are normalised to active/inactive.

Vehicle state of charge (ev_soc_sensor, %) – needed only for the related feature. Numeric state of charge between 0 and 100. Determines charging demand in SoC mode. Only required in SoC demand mode; percentage values are expected.

Required charging energy (ev_required_energy_sensor, kWh) – needed only for the related feature. Energy still required to reach the charging target. Provides charging demand in energy mode. Only required in energy demand mode; a positive kWh value is expected.

Planned driving distance (ev_planned_distance_sensor, km) – needed only for the related feature. Planned distance before the next charge. Derives charging demand in distance mode. Only required in distance demand mode; a positive kilometre value is expected.

What to check

  • Current heat-pump power: W · kW · MW
  • Heat-pump energy today: Wh · kWh · MWh
  • Outdoor temperature: °C · °F
  • Map optional sensors only with a matching unit
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Which input sensors does TFS (Toorox ForeSight HA) need

No separate sensor mapping: Toorox ForeSight HA works directly with the local SFML database.

In short

No separate sensor mapping: Toorox ForeSight HA works directly with the local SFML database. Local data source: Toorox ForeSight HA requires no separate Home Assistant sensor mapping.

SFML installation and local database (sfml_database, Lokale Datei) – required. Accessible SFML database with panel groups, forecast, and historical learning data. Provides local training and forecast context for Toorox ForeSight HA. No entity selection: Toorox ForeSight HA reads /config/solar_forecast_ml/solar_forecast.db directly from the local Home Assistant context.

What to check

  • SFML installation and local database: Lokale Datei
  • Map optional sensors only with a matching unit
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

SFML sensors: Forecast & production

Solar Forecast ML provides: Yield, power, and time-based solar forecasts for dashboards and automations.

In short

Forecast, actual production, learning quality, and diagnostics for the individual PV system. Yield, power, and time-based solar forecasts for dashboards and automations. For energy planning, dashboards, and forecast-based automations.

Forecast today (sensor.…_expected_daily_production, kWh) – provided (standard, always present). Shows forecast today as a current, locally processed value.

P10 planning forecast (sensor.…_conservative_planning_forecast, kWh) – provided (standard, always present). Shows p10 planning forecast as a current, locally processed value.

Remaining forecast today (sensor.…_today_forecast, kWh) – provided (standard, always present). Shows remaining forecast today as a current, locally processed value.

Forecast tomorrow (sensor.…_tomorrow_forecast, kWh) – provided (standard, always present). Shows forecast tomorrow as a current, locally processed value.

Forecast day after tomorrow (sensor.…_forecast_day_after_tomorrow, kWh) – provided (standard, always present). Shows forecast day after tomorrow as a current, locally processed value.

Next-hour forecast (sensor.…_next_hour_forecast, kWh) – provided (standard, always present). Shows next-hour forecast as a current, locally processed value.

Operational hybrid forecast (sensor.…_hybrid_forecast, kWh) – provided (standard, always present). Shows operational hybrid forecast as a current, locally processed value.

Hybrid forecast status (sensor.…_hybrid_forecast_status) – provided (standard, always present). Shows hybrid forecast status as a current, locally processed value.

Peak production hour (sensor.…_peak_production_hour) – provided (standard, always present). Shows peak production hour as a current, locally processed value.

Production time today (sensor.…_production_time, h) – provided (standard, always present). Shows production time today as a current, locally processed value.

Maximum peak today (sensor.…_max_peak_today, W) – provided (standard, always present). Shows maximum peak today as a current, locally processed value.

All-time peak (sensor.…_max_peak_all_time, W) – provided (standard, always present). Shows all-time peak as a current, locally processed value.

Total power (sensor.…_total_power, W) – provided (standard, always present). Shows total power as a current, locally processed value.

Actual yield today (sensor.…_total_actual_today, kWh) – provided (standard, always present). Shows actual yield today as a current, locally processed value.

Total yield today (sensor.…_total_yield, kWh) – provided (standard, always present). Shows total yield today as a current, locally processed value.

Power per panel group (sensor.…_panel_group_power, W) – provided (when configured). Shows power per panel group as a current, locally processed value.

Actual yield per panel group (sensor.…_panel_group_actual_today, kWh) – provided (when configured). Shows actual yield per panel group as a current, locally processed value.

evcc solar forecast (sensor.…_evcc_forecast) – provided (optional, appears when the feature is enabled). Shows evcc solar forecast as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

SFML sensors: Learning & forecast quality

Solar Forecast ML provides: Evaluation of the local learning basis and actual forecast quality.

In short

Forecast, actual production, learning quality, and diagnostics for the individual PV system. Evaluation of the local learning basis and actual forecast quality. For quality control and long-term evaluation of the system model.

Average monthly yield (sensor.…_average_yield, kWh) – provided (standard, always present). Shows average monthly yield as a current, locally processed value.

Average yield 7 days (sensor.…_avg_yield_7d, kWh) – provided (standard, always present). Shows average yield 7 days as a current, locally processed value.

Average yield 30 days (sensor.…_avg_yield_30d, kWh) – provided (standard, always present). Shows average yield 30 days as a current, locally processed value.

Weekly yield (sensor.…_weekly_yield, kWh) – provided (standard, always present). Shows weekly yield as a current, locally processed value.

Weekly consumption (sensor.…_weekly_consumption, kWh) – provided (standard, always present). Shows weekly consumption as a current, locally processed value.

Monthly yield (sensor.…_monthly_yield, kWh) – provided (standard, always present). Shows monthly yield as a current, locally processed value.

Monthly consumption (sensor.…_monthly_consumption, kWh) – provided (standard, always present). Shows monthly consumption as a current, locally processed value.

Average accuracy 30 days (sensor.…_avg_accuracy_30d, %) – provided (standard, always present). Shows average accuracy 30 days as a current, locally processed value.

Evaluation coverage 7 days (sensor.…_evaluation_coverage_7d, %) – provided (standard, always present). Shows evaluation coverage 7 days as a current, locally processed value.

Evaluation coverage 30 days (sensor.…_evaluation_coverage_30d, %) – provided (standard, always present). Shows evaluation coverage 30 days as a current, locally processed value.

Excluded MPPT hours 7 days (sensor.…_excluded_mppt_hours_7d, h) – provided (standard, always present). Shows excluded mppt hours 7 days as a current, locally processed value.

Excluded MPPT hours 30 days (sensor.…_excluded_mppt_hours_30d, h) – provided (standard, always present). Shows excluded mppt hours 30 days as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

SFML sensors: Diagnostics & data status

Solar Forecast ML provides: Technical states, data foundation, and integration freshness.

In short

Forecast, actual production, learning quality, and diagnostics for the individual PV system. Technical states, data foundation, and integration freshness. For troubleshooting, maintenance, and status monitoring.

System status (sensor.…_system_status) – provided (standard, always present). Shows system status as a current, locally processed value.

Data files status (sensor.…_data_files_status) – provided (standard, always present). Shows data files status as a current, locally processed value.

Workflow status (sensor.…_workflow_status) – provided (standard, always present). Shows workflow status as a current, locally processed value.

External sensors status (sensor.…_external_sensors_status) – provided (optional, appears when the feature is enabled). Shows external sensors status as a current, locally processed value.

Next production start (sensor.…_next_production_start) – provided (optional, appears when the feature is enabled). Shows next production start as a current, locally processed value.

AI status (sensor.…_ml_metrics) – provided (optional, appears when the feature is enabled). Shows ai status as a current, locally processed value.

AI RMSE (sensor.…_ai_rmse) – provided (optional, appears when the feature is enabled). Shows ai rmse as a current, locally processed value.

Active prediction model (sensor.…_active_prediction_model) – provided (optional, appears when the feature is enabled). Shows active prediction model as a current, locally processed value.

Physics samples (sensor.…_physics_samples) – provided (optional, appears when the feature is enabled). Shows physics samples as a current, locally processed value.

Last coordinator update (sensor.…_last_update_timestamp) – provided (optional, appears when the feature is enabled). Shows last coordinator update as a current, locally processed value.

Last AI training (sensor.…_last_ai_training) – provided (optional, appears when the feature is enabled). Shows last ai training as a current, locally processed value.

Next scheduled update (sensor.…_next_scheduled_update) – provided (optional, appears when the feature is enabled). Shows next scheduled update as a current, locally processed value.

Coordinator health (sensor.…_coordinator_health) – provided (optional, appears when the feature is enabled). Shows coordinator health as a current, locally processed value.

End-of-day duration (sensor.…_eod_duration, s) – provided (optional, appears when the feature is enabled). Shows end-of-day duration as a current, locally processed value.

Pause learning (switch.…_pause_learning) – provided (optional, appears when the feature is enabled). Shows pause learning as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

SFML sensors: Environment & system effects

Solar Forecast ML provides: Detected shading, weather dynamics, and model drift.

In short

Forecast, actual production, learning quality, and diagnostics for the individual PV system. Detected shading, weather dynamics, and model drift. For interpreting yield deviations and unusual system behaviour.

Yesterday forecast deviation (sensor.…_yesterday_deviation, %) – provided (optional, appears when the feature is enabled). Shows yesterday forecast deviation as a current, locally processed value.

Cloud trend 1 hour (sensor.…_cloudiness_trend_1h) – provided (optional, appears when the feature is enabled). Shows cloud trend 1 hour as a current, locally processed value.

Cloud trend 3 hours (sensor.…_cloudiness_trend_3h) – provided (optional, appears when the feature is enabled). Shows cloud trend 3 hours as a current, locally processed value.

Weather stability (sensor.…_cloudiness_volatility) – provided (optional, appears when the feature is enabled). Shows weather stability as a current, locally processed value.

Current shading (sensor.…_shadow_current) – provided (standard, always present). Shows current shading as a current, locally processed value.

Shading today (sensor.…_shadow_today) – provided (standard, always present). Shows shading today as a current, locally processed value.

Performance loss today (sensor.…_performance_loss_today, %) – provided (standard, always present). Shows performance loss today as a current, locally processed value.

AI drift status (sensor.…_drift_status) – provided (standard, always present). Shows ai drift status as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

STATS sensors: Prices & time windows

Solar Forecast STATS provides: Current and forward-looking electricity prices plus favourable time windows.

In short

STATS is primarily an interface. It additionally provides only the Home Assistant entities listed here. Price and cheap-energy entities appear when GPM is available. From V46.2.0, Smart Charge lives in STATS, not GPM. Interface charts are not separate sensors. Current and forward-looking electricity prices plus favourable time windows. For tariff dashboards and price-based automations.

Spot price (sensor.…_spot_price, ct/kWh) – provided (when configured). Shows spot price as a current, locally processed value.

Total price (sensor.…_total_price, ct/kWh) – provided (when configured). Shows total price as a current, locally processed value.

Spot price next hour (sensor.…_spot_price_next_hour, ct/kWh) – provided (when configured). Shows spot price next hour as a current, locally processed value.

Total price next hour (sensor.…_total_price_next_hour, ct/kWh) – provided (when configured). Shows total price next hour as a current, locally processed value.

Cheapest hour today (sensor.…_cheapest_hour_today, h) – provided (when configured). Shows cheapest hour today as a current, locally processed value.

Most expensive hour today (sensor.…_most_expensive_hour_today, h) – provided (when configured). Shows most expensive hour today as a current, locally processed value.

Average price today (sensor.…_average_price_today, ct/kWh) – provided (when configured). Shows average price today as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

STATS sensors: Battery & Smart Charge

Solar Forecast STATS provides: Local signals for battery power, charged energy, and charging plans.

In short

STATS is primarily an interface. It additionally provides only the Home Assistant entities listed here. Price and cheap-energy entities appear when GPM is available. From V46.2.0, Smart Charge lives in STATS, not GPM. Interface charts are not separate sensors. Local signals for battery power, charged energy, and charging plans. For storage statistics and custom charging automations.

PV surplus available (binary_sensor.…_surplus_available) – provided (standard, always present). Clearly signals whether “PV surplus available” is active.

Cheap energy (binary_sensor.…_cheap_energy) – provided (when configured). Clearly signals whether “Cheap energy” is active.

Smart charging active (binary_sensor.…_smart_charging) – provided (when configured). Clearly signals whether “Smart charging active” is active.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

STATS sensors: Thresholds & controls

Solar Forecast STATS provides: Configurable entities for price thresholds and Smart Charge.

In short

STATS is primarily an interface. It additionally provides only the Home Assistant entities listed here. Price and cheap-energy entities appear when GPM is available. From V46.2.0, Smart Charge lives in STATS, not GPM. Interface charts are not separate sensors. Configurable entities for price thresholds and Smart Charge. To set thresholds and operating modes directly in Home Assistant.

Smart charging (switch.…_smart_charging_enabled) – provided (standard, always present). Shows smart charging as a current, locally processed value.

Smart charging mode (select.…_smart_charging_mode) – provided (standard, always present). Shows smart charging mode as a current, locally processed value.

Target SoC (number.…_target_soc, %) – provided (standard, always present). Shows target soc as a current, locally processed value.

Minimum SoC (number.…_min_soc, %) – provided (standard, always present). Shows minimum soc as a current, locally processed value.

Maximum SoC (number.…_max_soc, %) – provided (standard, always present). Shows maximum soc as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

GPM sensors: Prices & time windows

Grid Price Monitor provides: Current and forward-looking electricity prices plus favourable time windows.

In short

Price values, cheap-energy signal, and optional storage charge history. Smart Charge lives in STATS. Tariffs are configured only in GPM. The former GPM smart-charging sensors were removed. Current and forward-looking electricity prices plus favourable time windows. For tariff dashboards and price-based automations.

Spot price (sensor.…_spot_price, ct/kWh) – provided (standard, always present). Shows spot price as a current, locally processed value.

Total price (sensor.…_total_price, ct/kWh) – provided (standard, always present). Shows total price as a current, locally processed value.

Spot price next hour (sensor.…_spot_price_next_hour, ct/kWh) – provided (standard, always present). Shows spot price next hour as a current, locally processed value.

Total price next hour (sensor.…_total_price_next_hour, ct/kWh) – provided (standard, always present). Shows total price next hour as a current, locally processed value.

Prices today (sensor.…_prices_today) – provided (standard, always present). Shows prices today as a current, locally processed value.

Prices tomorrow (sensor.…_prices_tomorrow) – provided (standard, always present). Shows prices tomorrow as a current, locally processed value.

Cheapest hour today (sensor.…_cheapest_hour_today, h) – provided (standard, always present). Shows cheapest hour today as a current, locally processed value.

Most expensive hour today (sensor.…_most_expensive_hour_today, h) – provided (standard, always present). Shows most expensive hour today as a current, locally processed value.

Average price today (sensor.…_average_price_today, ct/kWh) – provided (standard, always present). Shows average price today as a current, locally processed value.

Cheap energy (binary_sensor.…_cheap_energy) – provided (standard, always present). Clearly signals whether “Cheap energy” is active.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

GPM sensors: Battery & Smart Charge

Grid Price Monitor provides: Local signals for battery power, charged energy, and charging plans.

In short

Price values, cheap-energy signal, and optional storage charge history. Smart Charge lives in STATS. Tariffs are configured only in GPM. The former GPM smart-charging sensors were removed. Local signals for battery power, charged energy, and charging plans. For storage statistics and custom charging automations.

Battery power (sensor.…_battery_power, W) – provided (when configured). Shows battery power as a current, locally processed value.

Battery charged today (sensor.…_battery_charged_today, kWh) – provided (when configured). Shows battery charged today as a current, locally processed value.

Battery charged this week (sensor.…_battery_charged_week, kWh) – provided (when configured). Shows battery charged this week as a current, locally processed value.

Battery charged this month (sensor.…_battery_charged_month, kWh) – provided (when configured). Shows battery charged this month as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

GPM sensors: Thresholds & controls

Grid Price Monitor provides: Configurable entities for price thresholds and Smart Charge.

In short

Price values, cheap-energy signal, and optional storage charge history. Smart Charge lives in STATS. Tariffs are configured only in GPM. The former GPM smart-charging sensors were removed. Configurable entities for price thresholds and Smart Charge. To set thresholds and operating modes directly in Home Assistant.

Cheap price threshold (number.…_cheap_price, ct/kWh) – provided (standard, always present). Shows cheap price threshold as a current, locally processed value.

Force-charge price (number.…_force_charge_price, ct/kWh) – provided (standard, always present). Shows force-charge price as a current, locally processed value.

Below-average percent (number.…_below_average_pct, %) – provided (standard, always present). Shows below-average percent as a current, locally processed value.

Cheapest hours (number.…_cheapest_hours) – provided (standard, always present). Shows cheapest hours as a current, locally processed value.

Threshold mode (select.…_threshold_mode) – provided (standard, always present). Shows threshold mode as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

WFAI sensors: Weather intelligence

Weather Fusion AI provides: Local weather state, learning status, forecast quality, and concrete risk signals.

In short

One weather entity plus six diagnostics and learning sensors for local weather fusion. Local weather state, learning status, forecast quality, and concrete risk signals. For weather dashboards and robust weather-dependent automations.

Local weather forecast (weather.…_weather) – provided (standard, always present). Shows local weather forecast as a current, locally processed value.

Status (sensor.…_status) – provided (standard, always present). Shows status as a current, locally processed value.

Forecast accuracy (sensor.…_forecast_accuracy, %) – provided (standard, always present). Shows forecast accuracy as a current, locally processed value.

Learning progress (sensor.…_learning_progress, %) – provided (standard, always present). Shows learning progress as a current, locally processed value.

Active weather sources (sensor.…_active_sources) – provided (standard, always present). Shows active weather sources as a current, locally processed value.

Last learning update (sensor.…_last_learning_update) – provided (standard, always present). Shows last learning update as a current, locally processed value.

Cloud type (sensor.…_cloud_type) – provided (standard, always present). Shows cloud type as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

EAI sensors: Recommendations & planning

Solar Forecast EAI provides: Explainable recommendations for heat generation and flexible loads.

In short

Passive, explainable signals for heat pumps, wallboxes, and local weather risks. Optional groups appear only when the corresponding EAI function is enabled and configured. Explainable recommendations for heat generation and flexible loads. As a transparent decision basis; control remains in your automations.

Recommended action (sensor.…_recommended_action) – provided (standard, always present). Shows recommended action as a current, locally processed value.

Recommendation reason (sensor.…_recommendation_reason) – provided (standard, always present). Shows recommendation reason as a current, locally processed value.

Recommendation explanation (sensor.…_recommendation_explanation) – provided (standard, always present). Shows recommendation explanation as a current, locally processed value.

Recommendation confidence (sensor.…_recommendation_confidence, %) – provided (standard, always present). Shows recommendation confidence as a current, locally processed value.

Forecast uncertainty (sensor.…_forecast_uncertainty, %) – provided (standard, always present). Shows forecast uncertainty as a current, locally processed value.

Next recommended start (sensor.…_next_action_start) – provided (standard, always present). Shows next recommended start as a current, locally processed value.

Recommendation valid until (sensor.…_recommendation_valid_until) – provided (standard, always present). Shows recommendation valid until as a current, locally processed value.

Recommended duration (sensor.…_recommended_duration, min) – provided (standard, always present). Shows recommended duration as a current, locally processed value.

Consumption next hour (sensor.…_consumption_next_hour, kWh) – provided (standard, always present). Shows consumption next hour as a current, locally processed value.

Expected consumption today (sensor.…_consumption_today, kWh) – provided (standard, always present). Shows expected consumption today as a current, locally processed value.

Expected consumption tomorrow (sensor.…_consumption_tomorrow, kWh) – provided (standard, always present). Shows expected consumption tomorrow as a current, locally processed value.

Expected PV surplus (sensor.…_expected_pv_surplus, kWh) – provided (standard, always present). Shows expected pv surplus as a current, locally processed value.

Estimated cost advantage (sensor.…_estimated_cost_advantage, EUR) – provided (standard, always present). Shows estimated cost advantage as a current, locally processed value.

Data quality (sensor.…_data_quality, %) – provided (standard, always present). Shows data quality as a current, locally processed value.

Model status (sensor.…_model_status) – provided (standard, always present). Shows model status as a current, locally processed value.

Automation ready (binary_sensor.…_automation_ready) – provided (standard, always present). Clearly signals whether “Automation ready” is active.

PV window active (binary_sensor.…_pv_window_active) – provided (standard, always present). Clearly signals whether “PV window active” is active.

Hot water recommended (binary_sensor.…_dhw_recommended) – provided (standard, always present). Clearly signals whether “Hot water recommended” is active.

Heating recommended (binary_sensor.…_heating_recommended) – provided (standard, always present). Clearly signals whether “Heating recommended” is active.

Thermal storage recommended (binary_sensor.…_thermal_storage_recommended) – provided (standard, always present). Clearly signals whether “Thermal storage recommended” is active.

Low-price window active (binary_sensor.…_low_price_window_active) – provided (standard, always present). Clearly signals whether “Low-price window active” is active.

Operation deferrable (binary_sensor.…_operation_deferrable) – provided (standard, always present). Clearly signals whether “Operation deferrable” is active.

Critical data issue (binary_sensor.…_critical_data_issue) – provided (standard, always present). Clearly signals whether “Critical data issue” is active.

Automation signals (switch.…_automation_signals) – provided (standard, always present). Shows automation signals as a current, locally processed value.

PV optimisation (switch.…_pv_optimization) – provided (standard, always present). Shows pv optimisation as a current, locally processed value.

Tariff optimisation (switch.…_tariff_optimization) – provided (standard, always present). Shows tariff optimisation as a current, locally processed value.

Thermal loss status (sensor.…_thermal_loss_status) – provided (optional, appears when the feature is enabled). Shows thermal loss status as a current, locally processed value.

Thermal loss forecast (sensor.…_thermal_loss_forecast, kWh) – provided (optional, appears when the feature is enabled). Shows thermal loss forecast as a current, locally processed value.

Thermal loss data quality (sensor.…_thermal_loss_data_quality, %) – provided (optional, appears when the feature is enabled). Shows thermal loss data quality as a current, locally processed value.

Storage standby loss (sensor.…_storage_standby_loss, kWh) – provided (optional, appears when the feature is enabled). Shows storage standby loss as a current, locally processed value.

Circulation loss (sensor.…_circulation_loss, kWh) – provided (optional, appears when the feature is enabled). Shows circulation loss as a current, locally processed value.

Storage heat-loss coefficient (sensor.…_storage_heat_loss_coefficient) – provided (optional, appears when the feature is enabled). Shows storage heat-loss coefficient as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

EAI sensors: Wallbox

Solar Forecast EAI provides: Planning values and signals for forecast- and price-aware charging.

In short

Passive, explainable signals for heat pumps, wallboxes, and local weather risks. Optional groups appear only when the corresponding EAI function is enabled and configured. Planning values and signals for forecast- and price-aware charging. For custom wallbox automations and evaluating a charging window.

Recommended wallbox action (sensor.…_wallbox_recommended_action) – provided (optional, appears when the feature is enabled). Shows recommended wallbox action as a current, locally processed value.

Wallbox recommendation reason (sensor.…_wallbox_recommendation_reason) – provided (optional, appears when the feature is enabled). Shows wallbox recommendation reason as a current, locally processed value.

Wallbox recommendation explanation (sensor.…_wallbox_recommendation_explanation) – provided (optional, appears when the feature is enabled). Shows wallbox recommendation explanation as a current, locally processed value.

Wallbox recommendation confidence (sensor.…_wallbox_recommendation_confidence, %) – provided (optional, appears when the feature is enabled). Shows wallbox recommendation confidence as a current, locally processed value.

Wallbox forecast uncertainty (sensor.…_wallbox_forecast_uncertainty, %) – provided (optional, appears when the feature is enabled). Shows wallbox forecast uncertainty as a current, locally processed value.

Next wallbox start (sensor.…_wallbox_next_start) – provided (optional, appears when the feature is enabled). Shows next wallbox start as a current, locally processed value.

Recommended wallbox end (sensor.…_wallbox_recommended_end) – provided (optional, appears when the feature is enabled). Shows recommended wallbox end as a current, locally processed value.

Required charging energy (sensor.…_wallbox_required_energy, kWh) – provided (optional, appears when the feature is enabled). Shows required charging energy as a current, locally processed value.

Expected PV share (sensor.…_wallbox_expected_pv_share, %) – provided (optional, appears when the feature is enabled). Shows expected pv share as a current, locally processed value.

Estimated charging cost (sensor.…_wallbox_estimated_cost, EUR) – provided (optional, appears when the feature is enabled). Shows estimated charging cost as a current, locally processed value.

Estimated charging advantage (sensor.…_wallbox_estimated_cost_advantage, EUR) – provided (optional, appears when the feature is enabled). Shows estimated charging advantage as a current, locally processed value.

Departure readiness (sensor.…_wallbox_departure_readiness, %) – provided (optional, appears when the feature is enabled). Shows departure readiness as a current, locally processed value.

Wallbox data quality (sensor.…_wallbox_data_quality, %) – provided (optional, appears when the feature is enabled). Shows wallbox data quality as a current, locally processed value.

Wallbox charging window active (binary_sensor.…_wallbox_charging_window_active) – provided (optional, appears when the feature is enabled). Clearly signals whether “Wallbox charging window active” is active.

PV charging recommended (binary_sensor.…_wallbox_pv_charging_recommended) – provided (optional, appears when the feature is enabled). Clearly signals whether “PV charging recommended” is active.

Residual PV window active (binary_sensor.…_wallbox_residual_pv_window_active) – provided (optional, appears when the feature is enabled). Clearly signals whether “Residual PV window active” is active.

Low-price charging recommended (binary_sensor.…_wallbox_low_price_charging_recommended) – provided (optional, appears when the feature is enabled). Clearly signals whether “Low-price charging recommended” is active.

Departure risk (binary_sensor.…_wallbox_departure_risk) – provided (optional, appears when the feature is enabled). Clearly signals whether “Departure risk” is active.

Wallbox optimisation (switch.…_wallbox_optimization) – provided (optional, appears when the feature is enabled). Shows wallbox optimisation as a current, locally processed value.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

EAI sensors: Weather intelligence

Solar Forecast EAI provides: Local weather state, learning status, forecast quality, and concrete risk signals.

In short

Passive, explainable signals for heat pumps, wallboxes, and local weather risks. Optional groups appear only when the corresponding EAI function is enabled and configured. Local weather state, learning status, forecast quality, and concrete risk signals. For weather dashboards and robust weather-dependent automations.

Weather intelligence status (sensor.…_weather_intelligence_status) – provided (optional, appears when the feature is enabled). Shows weather intelligence status as a current, locally processed value.

Weather data quality (sensor.…_weather_data_quality, %) – provided (optional, appears when the feature is enabled). Shows weather data quality as a current, locally processed value.

Paired weather samples (sensor.…_weather_paired_samples) – provided (optional, appears when the feature is enabled). Shows paired weather samples as a current, locally processed value.

Temperature bias (sensor.…_weather_temperature_bias, °C) – provided (optional, appears when the feature is enabled). Shows temperature bias as a current, locally processed value.

Temperature MAE (sensor.…_weather_temperature_mae, °C) – provided (optional, appears when the feature is enabled). Shows temperature mae as a current, locally processed value.

Temperature uncertainty (sensor.…_weather_temperature_uncertainty, °C) – provided (optional, appears when the feature is enabled). Shows temperature uncertainty as a current, locally processed value.

Weather forecast confidence (sensor.…_weather_forecast_confidence, %) – provided (optional, appears when the feature is enabled). Shows weather forecast confidence as a current, locally processed value.

Weather forecast valid until (sensor.…_weather_forecast_valid_until) – provided (optional, appears when the feature is enabled). Shows weather forecast valid until as a current, locally processed value.

Active weather event (sensor.…_weather_active_event) – provided (optional, appears when the feature is enabled). Shows active weather event as a current, locally processed value.

Most important weather warning (sensor.…_weather_most_important_warning) – provided (optional, appears when the feature is enabled). Shows most important weather warning as a current, locally processed value.

Next weather event (sensor.…_weather_next_event) – provided (optional, appears when the feature is enabled). Shows next weather event as a current, locally processed value.

Next weather event start (sensor.…_weather_next_event_start) – provided (optional, appears when the feature is enabled). Shows next weather event start as a current, locally processed value.

Next weather event end (sensor.…_weather_next_event_end) – provided (optional, appears when the feature is enabled). Shows next weather event end as a current, locally processed value.

Next weather event severity (sensor.…_weather_next_event_severity) – provided (optional, appears when the feature is enabled). Shows next weather event severity as a current, locally processed value.

Weather event today (sensor.…_weather_event_today) – provided (optional, appears when the feature is enabled). Shows weather event today as a current, locally processed value.

Weather event tomorrow (sensor.…_weather_event_tomorrow) – provided (optional, appears when the feature is enabled). Shows weather event tomorrow as a current, locally processed value.

Weather event day after tomorrow (sensor.…_weather_event_day_after_tomorrow) – provided (optional, appears when the feature is enabled). Shows weather event day after tomorrow as a current, locally processed value.

Precipitation next 24 hours (sensor.…_weather_precipitation_next_24h, mm) – provided (optional, appears when the feature is enabled). Shows precipitation next 24 hours as a current, locally processed value.

Precipitation probability next 24 hours (sensor.…_weather_precipitation_probability_next_24h, %) – provided (optional, appears when the feature is enabled). Shows precipitation probability next 24 hours as a current, locally processed value.

Minimum temperature next 24 hours (sensor.…_weather_temperature_min_next_24h, °C) – provided (optional, appears when the feature is enabled). Shows minimum temperature next 24 hours as a current, locally processed value.

Maximum temperature next 24 hours (sensor.…_weather_temperature_max_next_24h, °C) – provided (optional, appears when the feature is enabled). Shows maximum temperature next 24 hours as a current, locally processed value.

Maximum wind next 24 hours (sensor.…_weather_wind_speed_max_next_24h, km/h) – provided (optional, appears when the feature is enabled). Shows maximum wind next 24 hours as a current, locally processed value.

Weather alert active (binary_sensor.…_weather_alert_active) – provided (optional, appears when the feature is enabled). Clearly signals whether “Weather alert active” is active.

Frost risk (binary_sensor.…_weather_frost_risk) – provided (optional, appears when the feature is enabled). Clearly signals whether “Frost risk” is active.

Heavy-rain risk (binary_sensor.…_weather_heavy_rain_risk) – provided (optional, appears when the feature is enabled). Clearly signals whether “Heavy-rain risk” is active.

High-wind risk (binary_sensor.…_weather_high_wind_risk) – provided (optional, appears when the feature is enabled). Clearly signals whether “High-wind risk” is active.

Heat-stress risk (binary_sensor.…_weather_heat_stress_risk) – provided (optional, appears when the feature is enabled). Clearly signals whether “Heat-stress risk” is active.

Weather forecast stale (binary_sensor.…_weather_forecast_stale) – provided (optional, appears when the feature is enabled). Clearly signals whether “Weather forecast stale” is active.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

TFS sensors: Local API signals

Toorox ForeSight HA provides: API responses provided locally by Toorox ForeSight for SFML and STATS.

In short

Toorox ForeSight HA does not provide native Home Assistant sensors. Results are passed locally to SFML and STATS through an API. The following items are API contracts, not entities in the Home Assistant entity registry. API responses provided locally by Toorox ForeSight for SFML and STATS. For internal integration with SFML and STATS—not as a native Home Assistant entity.

Service, version, and model status (API) – provided (standard, always present). Returns Service, version, and model status as a structured local API result.

P50 forecast per hour and panel group (API, kWh) – provided (standard, always present). Returns P50 forecast per hour and panel group as a structured local API result.

P10, P50, and P90 forecast (API, kWh) – provided (standard, always present). Returns P10, P50, and P90 forecast as a structured local API result.

Validation, horizon, and generation time (API) – provided (standard, always present). Returns Validation, horizon, and generation time as a structured local API result.

Adaptation and training status (API) – provided (standard, always present). Returns Adaptation and training status as a structured local API result.

What to check

  • Integration installed and loaded
  • Optional entities: feature enabled and configured
  • Entity not disabled in the Home Assistant registry
View sensors & entities

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Which rain sensor does SFML need

SFML Core expects current physical precipitation in mm/h—not a daily total or yes-no sensor.

In short

Select the current reading from a local weather station. The value must be numeric and describe precipitation per hour in mm/h. A daily total or cumulative event counter represents something different and distorts the weather context.

Weather Fusion AI can accept accumulated rain values in specific setup fields. Always follow the description of the exact field rather than relying on an entity name containing the word rain.

What to check

  • Unit is mm/h
  • Sensor provides a current reading
  • Not a daily total or binary sensor
  • Omit the optional input when readings are unreliable
Open required sensors

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why is my sensor not offered for selection

Home Assistant filters many selectors by device class and unit. An existing entity can still be technically unsuitable.

In short

The selector only shows entities matching the expected data type. A power field expects a numeric power sensor, so a custom helper without the correct device class may be absent even though it is visible in Developer Tools.

What to check

  • State is numeric and not unknown
  • Unit matches the setup field
  • Device class is correct
  • Entity remains available after a Home Assistant restart
Check sensor requirements

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Power or energy – which sensor type do I need

W and kW describe current power; Wh and kWh describe energy accumulated over time.

In short

Energy flows, current production, and current consumers usually require power sensors. Daily yield, grid import, or consumption histories are energy quantities. Swapping the two creates implausible flows, costs, and statistics.

Directional fields such as Grid → House expect a positive value for that direction only. Split a signed net sensor into import and export first. A field labelled today requires a counter since midnight; a lifetime cumulative total is unsuitable.

What to check

  • Power: W or kW
  • Energy: Wh or kWh
  • Do not place energy in a power field
  • Represent import and export as separate positive directions
  • A daily counter starts near zero after midnight

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What measurement does an active panel group require

Every active panel group needs installed capacity, orientation, tilt, and a live power sensor in W or kW.

In short

SFML integrates measured group power into daily energy itself. Separate daily-kWh helpers are not required for the current core setup. If no group value is available, check whether the inverter or local interface exposes a suitable string or MPPT sensor.

What to check

  • Installed group capacity is correct
  • Azimuth and tilt are correct
  • Live sensor provides W or kW
  • Sensor belongs to this panel group
Open installation guide

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Set up the wallbox and electric car

Which sensors make the wallbox visible, how it feeds the balance and the charging plan, and which switch must never be chosen.

In short

The basis is two values from your wallbox: current charging power in watts, and wallbox status, meaning whether it is charging, connected, or ready. With those, the wallbox appears in the consumption atlas and in the daily balance. Optional additions are the charging mode as a select entity and the energy of the current charging session in kilowatt-hours; they make a per-session view possible.

For charging plans the demand is added: the vehicle’s state of charge, the extra energy you want, or a planned trip with distance and consumption. From that come a suggested charging window, the expected solar share, and a comparison with charging immediately.

If you want energy management to release the wallbox, choose a switch that controls charging permission and can be turned off safely. Never the main switch or the wallbox power supply – switching off in the middle of a charge can put the vehicle and the wallbox into a fault state.

Read consumption figures in the right place: household consumption is the consumption of the house. Whether the wallbox and heat pump are already inside it depends on where your meter measures. If you also enter them as consumers, STATS recognises their share and does not count them twice.

What to check

  • Wallbox power in watts and wallbox status assigned
  • Optional charging mode and session energy added
  • Only a charging release that can be switched off safely is chosen as the release switch
  • Checked whether the wallbox is already inside household consumption
Kepler energy management

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Set up and read the heat pump

Required values for the heat view, useful additions, and how the consumption shows up in the balance.

In short

The heat view needs three entries: the heat pump’s current power consumption in watts, daily consumption in kilowatt-hours that resets to zero at midnight, and the heat-pump type. Thermal heating power and nominal COP are added so electrical power becomes a quantity of heat.

Optional but valuable: indoor temperature, target temperature, and domestic-hot-water mode. Only then can heating be told apart from hot-water production, and the behaviour of your building becomes visible.

Weather values do not have to be entered – they arrive automatically. You can add your own sensors for outdoor temperature, wind, humidity, air pressure, and precipitation when they measure closer to your site.

In STATS, also enter the heat pump as a consumer with its power. It then appears in the consumption atlas. Whether its consumption is already inside household consumption depends on your meter; STATS recognises the share and does not count it twice.

What to check

  • Power sensor in watts and daily energy in kWh are present
  • Daily energy resets to zero at midnight
  • Heat-pump type, heating power, and nominal COP entered
  • Heat pump entered in STATS as a consumer
Kepler energy managementEnergy Management System

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Set up Smart Charge

What GPM and STATS each do, what you enter once under Battery, and what On, mode, and the SoC limits do.

In short

Smart Charge needs Grid Price Monitor and Solar Forecast STATS. GPM knows the prices and decides which hours are cheap. STATS knows battery level, consumption, and the solar forecast from Solar Forecast ML, makes the charging decision, and switches. If GPM price signals are missing, STATS turns grid charging off.

The one-time setup is under Settings, Solar Forecast Stats, Configure, Battery. Battery capacity in kWh must be greater than zero, otherwise STATS does not calculate. Maximum charge power in kW caps how much grid energy enters the calculation in one hour; zero means unlimited. Choose the SoC sensor there as a battery entity. If none is chosen, STATS uses the battery level from the sensor assignment. It reads a value from 0 to 100 percent; without a readable value it does not charge. STATS takes inverter power from Solar Forecast ML. If it is missing or invalid, STATS calculates without that limit.

The charge switch must be an entity of the switch domain. The picker lists only switches, so an input_boolean does not appear. The switching control calls switch.turn_on and switch.turn_off and reads the state back until it matches the command. If an automation starts grid charging, create a template switch that reports the real state. Without a charge switch, STATS still calculates the recommendation and switches nothing.

On the Smart Charge page: On enables grid charging; off leaves the charge switch off. The mode decides where the demand comes from. Target SoC is the level charged up to when electricity is cheap. Min SoC is the floor below which the target is not set. Max SoC is the ceiling; STATS does not charge from the grid above it.

Fill the gap only takes from the grid just the amount that the solar forecast and consumption show as a gap, and waits when a later hour can cover it more cheaply. The configured target SoC plays no role in this mode. It suits you when the battery should take solar power first. Charge to target when power is cheap fills up to the target SoC in cheap hours and up to max SoC when the price is extremely cheap, without using the forecast as the target. It suits you when you want a fixed level as soon as electricity is cheap. Combined, where the higher need wins, takes the higher of the two demands and charges as soon as either path asks to charge. It suits you when neither the forecast gap nor the chosen fill level should be dropped.

What to check

  • GPM and STATS are installed, and GPM provides prices
  • Battery capacity is greater than zero
  • Maximum charge power is set, or left at zero on purpose
  • SoC sensor provides a value from 0 to 100 percent
  • Charge switch is a switch, not an input_boolean
  • With an automation, the template switch reports the real state
  • Mode chosen; target SoC expected only in price band or combined
Why does Smart Charge only analyse

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Changing panel groups: what happens to what was learned

When a change is needed, what it resets, and how to do it properly.

In short

A panel group describes a part of your system with its own orientation: power sensor, azimuth, tilt, and kWp. Up to four groups are possible. The split is not cosmetic – SFML learns each group on its own, because an east roof and a west roof deliver at completely different times of day.

If you change a group’s layout, sensor, or geometry, what was learned no longer fits the new split. The affected group practically starts over, while the other groups and the physical foundation keep working. The forecast stays usable, but it is less accurate for a few days.

So: set the groups up cleanly once, then leave them alone. Correct them when they are clearly wrong – wrong sensor, swapped orientation, wrong kWp – not as an experiment.

When modules are added, enter the new group and update the total capacity. When a group is removed, set the number of active groups back; leftover entries otherwise leave gaps.

What to check

  • Per group: the right power sensor, azimuth, tilt, kWp
  • Number of active groups matches the system
  • Total capacity in kWp matches the sum of the groups
  • Watch for a few days after the change instead of changing again
What measurement does an active panel group require

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What do Update Interval, Diagnostic Mode, and forecast sensors control

These options control the regular update interval and which additional SFML sensors Home Assistant provides.

In short

Update Interval sets the time between regular forecast updates in seconds. Values from 300 to 86,400 seconds are allowed; the default is 3,600 seconds. A value of 1,800, for example, means an update every 30 minutes.

Diagnostic Mode provides additional sensors for monitoring the data foundation, model, and system state. Hourly Forecast Sensor adds a dedicated next-hour sensor. evcc Solar Forecast provides hourly forecast data directly in the format expected by evcc, avoiding the need for a separate template sensor.

These additional sensors do not change the system configuration themselves. Enable them when you actually use their values for diagnostics, dashboards, automations, or evcc.

What to check

  • Enter the update interval in seconds
  • Use a value from 300 to 86,400 seconds
  • Enable Diagnostic Mode for extended status sensors
  • Enable the hourly and evcc outputs only when needed

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Which notifications can I control in Advanced Options

The switches control Home Assistant notifications for startup, forecasts, training, and detected weather conditions.

In short

Startup, Forecast, Training, and Success Notifications report integration startup, forecast updates, the start of training, and training completion. They let you choose how much information to receive without disabling the underlying process.

Fog, Frost, Weather Alert, and Snow Coverage Notifications report detected conditions. A Weather Alert means that measured weather differs unexpectedly from the forecast. Disabling a notification only suppresses that message; the underlying detection and forecasting remain active.

What to check

  • Enable only notifications that are useful in daily operation
  • Disable forecast or training messages if they become too frequent
  • Do not confuse weather detection with its notification switch
  • When notified, check the timestamp and affected sensor readings

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What do Adaptive Forecast and Winter Mode do

Adaptive Forecast can correct the afternoon; Winter Mode adds a cloud correction under narrowly defined conditions.

In short

Adaptive Forecast compares the morning forecast with actual production in the early afternoon. If the two differ clearly, SFML uses fresh weather data and further criteria to decide whether correcting the afternoon forecast is useful. The option permits this automatic correction; it does not force one. The default is OFF.

Winter Mode applies in the dark months at low sun angles. The additional cloud correction is used only when neither measured irradiance nor irradiance supplied by a weather provider is available. The default is ON.

What to check

  • Enable Adaptive Forecast only if automatic afternoon corrections are wanted
  • A clear deviation does not guarantee a correction
  • Normally leave Winter Mode enabled
  • Measured or provider-supplied irradiance takes priority over the winter cloud correction

✓Technically reviewed: SFML · STATS · EAI V52.0.4

How do I configure zero export and battery storage for curtailment detection

These options prevent the model from learning technically curtailed production as normal system behaviour.

In short

Enable Zero Export only when a controller limits inverter production to household demand. During suitable weather and when production is clearly below the physics forecast, SFML then looks for curtailed hours and excludes detected cases from ML training.

Enable Battery Storage System only when a battery is actually present. A Solar-to-Battery Power Sensor then becomes mandatory. It must provide the current PV-to-battery power in W or kW. If this flow falls below 50 W under suitable conditions, that can indicate a full battery and MPPT curtailment together with the other criteria. A low sensor value alone is not a reliable finding.

Max Allowed Grid Export describes an actual export or AC output limit in watts. With Zero Export enabled, SFML stores 0 W internally. Without Zero Export, the real limit helps classify production that remains capped at that boundary as possible curtailment.

What to check

  • Enable Zero Export only when a controller is present
  • Select a Solar-to-Battery sensor whenever Battery Storage is enabled
  • The sensor must provide current power, not energy
  • Enter the actual export or AC output limit in watts
  • Assess training exclusions together with weather, physics forecast, and measurement quality

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Inverter limit, clipping, and zero export

When to enter the AC limit, what it does, and why curtailed hours do not belong in learning.

In short

The inverter AC limit is the ceiling your system cannot exceed after the inverter – for example 10 kW on a 13 kWp system. If you enter it, SFML knows that hours at this ceiling do not show the possible irradiance, but a technical limit. Without this entry, SFML treats clipped hours as reality and learns a system that is too weak.

Zero export does the same for a different reason: when the battery is full and household consumption is covered, the system ramps down. Those hours also do not show what would have been possible. For SFML to recognise that, it needs the battery-storage entries and the maximum allowed grid export.

If you have no limit, leave the field empty or at zero. A wrong value does more harm than no value.

SFML does not relearn the past. After you correct these entries, the forecast improves with the following days, not immediately.

What to check

  • AC limit matches the actual inverter, not the module capacity
  • With zero export: battery storage and maximum allowed grid export entered
  • Without a limit: field empty or zero
  • Watch for a few days after the change
How do I configure zero export and battery storage for curtailment detection

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What is the Pirate Weather API Key for

The optional key adds NOAA GFS/HRRR data to weather blending, especially for assessing cloud cover.

In short

A Pirate Weather API Key lets SFML use the NOAA GFS/HRRR weather model as an additional weather source. Its data contributes to weather blending and can improve the assessment of cloud cover in particular.

The key is optional. Without it, SFML continues using the other available weather sources. Treat the API key as a secret and do not publish it in screenshots, logs, or support posts.

What to check

  • Enter the complete API key without surrounding spaces
  • Do not share the key publicly
  • After saving, check weather-source availability
  • Leave the field empty when Pirate Weather is not used
Get a Pirate Weather API key

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why is a new forecast still inaccurate

A new installation initially has little local evidence. Individual days are not enough to assess the system model reliably.

In short

Check the technical data foundation first, then evaluate the forecast across several suitable days. Changing weather, shading, curtailment, and incomplete readings can heavily distort individual comparisons.

One low-error day does not prove that a model is finished, just as one high-error first day does not prove a defect.

What to check

  • Every active group provides plausible power
  • System geometry is correct
  • No outage or curtailment distorted the period
  • Diagnostics show complete and current data

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why are hours excluded from learning

An exclusion protects the local system model from incomplete, technically limited, or unreliable measurements.

In short

SFML only learns from hours whose measurements form a reliable foundation. If measured production differs substantially from the expected profile, part of an hour is missing, or technical indicators suggest a limitation, that hour is excluded as a precaution. This is not initially an error; it protects the system model from unsuitable learning data.

The accu_curtailment message is a generic protective classification. It does not mean that a battery must be present or that a battery definitely curtailed production. It can also be triggered without a battery—for example by unexplained MPPT curtailment, an incompletely captured production hour, a brief Home Assistant interruption, a temporarily unstable inverter connection, or missing, delayed, or erratic measurements.

Related technical reasons include suspected_battery_curtailment, demand_limited_zero_export, zero_export_limited, full_battery_zero_export, full_battery_export_limit, transition_curtailment, mppt_throttled, and inverter_clipped. These labels explain why an hour was not accepted as a safe learning foundation. They are not a final diagnosis of the technical cause.

Typical original messages begin with Excluding <hour> from learning: <reason> or Learning filter: Excluded <count> hours (<remaining> remaining). Reasons: <reasons>. If too few suitable production hours remain, Daily learning skipped: Too many excluded hours may also appear. SFML then skips learning for that day instead of changing the model with an insufficient or distorted data foundation.

In STATS, these hours appear as exclusions and are not part of clean quality. Learning basis, coverage, and total error can therefore use different hour sets and should be read together.

What to check

  • Confirm that the complete production hour was captured
  • Check for Home Assistant restarts or brief interruptions at the same time
  • Check the inverter connection for interruptions
  • Inspect the production sensor for missing, flat, or erratic values
  • Check for limits caused by the inverter, MPPT, zero export, or battery
  • Observe whether the exclusion is isolated or repeats at the same time

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What does AI not trained mean

There is not yet enough suitable local evidence for an active trained model.

In short

SFML can continue forecasting with its physical foundation. An additional model is only used after enough suitable data has been collected and internal evaluation has passed. The status alone does not call for a reset or manual database change.

What to check

  • Run the installation long enough with complete data
  • Check learning and data-quality sensors
  • Avoid frequent sensor changes during learning
  • Check versions and daily routines for errors

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What does Pending Candidate mean

A newly trained model is evaluated in parallel and does not affect the active forecast until it passes that evaluation.

In short

A Pending Candidate is a newly trained model that is still being evaluated. It initially runs alongside the model currently in use and collects comparison data. During this period, it does not affect the active forecast.

The progress counter increases by one day when enough valid comparison data is available for a calendar day. This requires complete regularly scheduled forecast runs and usable measurements. Manual test runs, duplicate runs, or days with missing or excluded measurements do not increase the counter.

A new model candidate runs in parallel and is checked against the active model on comparable days. The decision comes only once enough meaningful days have accumulated: the candidate is adopted, discarded, or the check continues, for example because rare weather situations are still missing. A note that the candidate has merely been around for a while does not mean the check is finished.

The Pending Candidates count itself increases only when another unevaluated model candidate is created. During normal operation, no more than one candidate is pending at a time.

What to check

  • Do not equate the progress counter with the candidate's age
  • Count only complete regularly scheduled forecast runs as potential evidence days
  • Account for missing or excluded measurements during the evaluation period
  • Expect the decision only once enough meaningful days have accumulated

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What does critical AI drift mean

Drift describes a substantial change between learned system behaviour and current observations—not automatically a defect.

In short

Season, moving shade, snow, dirt, technical limits, or changed sensors can trigger drift. What matters is whether the state persists together with poor data quality or unusual forecasts.

Do not delete the learning database because the label says critical. First check what changed in the system, weather, sensors, or configuration.

What to check

  • Sensors and system configuration were not changed
  • No shading, dirt, or curtailment was overlooked
  • Readings remain plausible and complete
  • Evaluate forecast quality across several suitable days

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Database size, retention, and the Home Assistant recorder

Why SFML keeps its own database, how large it gets, and what the recorder has to do with it.

In short

SFML and STATS store their measurement series, forecasts, and learning data in their own database, separate from the Home Assistant recorder. That is intentional: the recorder is built for short retention, while forecast quality can only be judged over months and years.

The own database grows continuously, but within a modest range; older detail is compacted or discarded by fixed rules. Regular manual cleanup is not provided and not needed.

If your Home Assistant database grows large, that is usually the recorder, not SFML. The usual remedies help there: shorten retention and exclude entities you do not need historically. That does not affect the SFML evaluations.

Resetting the learning database is the last step, not the first. It is the basis of every learned pattern; after a reset, learning starts over. Before you do that, check the usual causes of a poor forecast: wrong sensors, a missing AC limit, badly cut panel groups.

What to check

  • Look at the size of the Home Assistant database from the recorder, not from SFML
  • Recorder retention and excluded entities checked
  • Configuration checked before a reset
  • Enough free storage on the system
When should I reset the learning database

✓Technically reviewed: SFML · STATS · EAI V52.0.4

When should I reset the learning database

A reset removes valuable local history and is not the standard response to warnings, drift, or one poor forecast.

In short

Correct the cause first: a wrong sensor mapping, unsuitable unit, system change, or data gap. Use supported diagnostics and correction paths before discarding the full learning foundation.

A full restart is only appropriate when the history is demonstrably unusable and a targeted correction cannot repair it. Back up the data first.

What to check

  • The cause is clearly identified
  • Current configuration is correct
  • A targeted correction is insufficient
  • An SFML data backup exists

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Moving to a new Home Assistant instance

What a backup takes with it, what you check after the move, and how you keep what was learned.

In short

A full Home Assistant backup contains the integrations with their configuration and the data directories of the add-on components. If it is restored completely on the new instance, settings and learned data come with it.

The entities are the critical part: if your sensors have different names on the new instance – for example because a device was added again – the fields point at nothing. Then you assign them once more. Everything learned stays, as long as the sensor is the same in substance.

After the move, the same quiet period applies as after an update: restart fully once, wait through a daily cycle, then judge the forecast and the statistics.

What you should avoid: setting the integration up fresh on the new instance even though a backup exists. That makes learning start over.

What to check

  • A full backup, not only the configuration files
  • Every sensor assignment checked after the restore
  • Restarted fully once and a day waited
  • Licence checked on the new instance
What I should check after an update

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Record the electricity bill, yearly history, and monthly correction

What the “My electricity bill” card shows, what the yearly history is for, and when you need the monthly correction.

In short

On the electricity-price page two things sit side by side and stay deliberately separate. ‘My electricity bill’ calculates only from measured data: your hourly values from STATS and the hourly prices from GPM. This card does not look at invoices. It shows what your sensors measured and where that lands you at the end of the year.

The ‘yearly history’ below is your invoice book. You enter what the bill says: period, grid import, amount, provider. From that come consumption, cost, and the real price per kilowatt-hour for each year – including years that still have no measurements. Provider changes and price adjustments are split by the day, not added up as a flat figure.

Why separate? The provider’s meter reading, your own sensors, and billing periods never match exactly. Side by side, both numbers mean something; mixed together, neither would stay traceable. The comparison is exactly where sensor errors or back-payments show up.

The monthly correction is something else: it changes GPM’s hourly prices. You enter consumption and the billed amount for a closed month, and GPM shifts the hourly prices so the month averages to the price you actually paid. You only need this when the prices in GPM were wrong – for example a missing levy, a tariff change, or outages. ‘Edit bill’ only changes your entry in the invoice book and does not touch the hourly prices.

With time-of-use tariffs you do not have to import a price list: create the windows with start, end, price, and weekdays in the GPM options, and GPM builds the hourly prices itself. CSV import is for dynamic tariffs and for filling in past periods.

What to check

  • Bills recorded in full with period, grid import, and amount
  • Time windows created when the tariff has time zones
  • Monthly correction only for closed months with a visible difference
  • After the correction, monthly values checked against the bill
Energy & financeWhy does STATS show unrealistic electricity costs

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why does STATS show unrealistic electricity costs

Extreme costs or energy values often come from swapped power and energy, incorrect scaling, or an unsuitable tariff input.

In short

Check the input sensors and units first. A kWh value in a W field, or a kW value interpreted as W, shifts calculations by large factors. Then verify electricity price, grid import, and signs.

From V46.2.0 the total price comes only from GPM (total_price in ct/kWh). STATS no longer has its own tariff input sensor. An exchange price without network fees, taxes, and surcharges is not the total price and can distort costs and Smart Charge.

What to check

  • Power fields contain W or kW
  • Energy fields contain Wh or kWh
  • GPM is installed and provides total_price in ct/kWh
  • The GPM tariff contains the intended price components
  • Import and export are not swapped

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why can STATS and the forecast appear different

STATS visualises stored values and states; a display issue is not automatically a forecasting-code defect.

In short

Distinguish the technical forecast, its storage, and its visual presentation. Lines, cards, or delayed analysis values can look different while the operational forecast is correct.

Compare the related SFML sensors and timestamps before inferring a forecasting defect from a graphic. When Modern marks a value stale or offline, it is keeping the last known state visible. A Home Assistant restart after backend updates followed by a hard refresh may be required.

What to check

  • Compare the related SFML sensor
  • Check timestamp and freshness
  • Note stale or offline status
  • Perform a browser hard refresh
  • Use a current and matching STATS version

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What do available and used weather sources mean

Available describes reachable sources; used describes the subset selected for a particular evaluation.

In short

Not every reachable source has to be used equally or at all at every point in time. Availability, completeness, and learned local quality influence selection, so the numbers may differ.

What to check

  • Additional API credentials are valid
  • Local weather sensors provide current data
  • No source is permanently unavailable
  • Observe the assessment over several updates

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Why does the SFML start notification repeat

Repeated start messages may indicate that Home Assistant or the integration is restarting or reloading.

In short

First check whether Home Assistant restarted or the process was restarted because of memory pressure, add-ons, or host issues. The message alone does not prove an SFML defect.

What to check

  • Check Home Assistant uptime
  • Check host and Core logs at the same time
  • Observe RAM and storage use
  • Compare restart messages from other integrations

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What is the Energy Management System

Since V44.2.0, EMS is included locally in EAI and uses Kepler to judge what makes sense for heating, storage, and mobility.

In short

The Energy Management System combines the local solar forecast with heat demand, storage, and charging plans. Kepler supports that evaluation. The result is recommendations and releases, not cloud processing and not direct device control.

Hubble remains at its provisional final state for solar forecasting; further Hubble changes are limited to bug fixes. SFML, STATS, and EAI should be on V44.2.0 or newer together.

What to check

  • EAI license is valid
  • SFML and STATS are configured
  • SFML, STATS, and EAI are V44.2.0 or newer
  • EAI does not switch devices itself
View EMS in featuresSet up EAI

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Is my hardware sufficient for the full suite

SFML Core and the full stack create different loads. STATS, EAI, and other modules increase memory, database, and compute requirements.

In short

On limited hardware, install only components you genuinely use. The decisive factor is not just CPU core count, but available headroom for Home Assistant, its database, add-ons, and daily learning routines.

Long routines are not automatically errors. Repeated timeouts, restarts, full memory, or missing sensor updates indicate insufficient headroom.

What to check

  • Observe RAM use and restarts
  • Check duration of daily routines
  • Watch for database timeouts
  • Disable unused optional modules

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Understand and reduce system load

When load is normal, how you recognise a real overload, and which adjustments exist.

In short

The main calculation runs once a day. In those minutes processor load rises clearly – that is normal and not a fault. What matters is whether the load falls again afterwards.

Lasting high load usually has other causes: an update interval that is too short, very many integrations running at once, an overloaded storage device, or a very large Home Assistant database. An SD card as the system drive is the most common single cause.

Adjustments, in this order: raise the update interval, turn diagnostic mode off when you do not need it, tidy the recorder, and if possible switch from an SD card to an SSD.

For scale: on weak hardware the daily calculation can take a noticeable time. As long as the results are complete and the system runs quietly again afterwards, that is not a fault.

What to check

  • Load falls again after the daily calculation
  • Update interval checked and not needlessly low
  • Diagnostic mode only on when needed
  • System drive: SSD instead of an SD card
  • Recorder database at a reasonable size
Is my hardware sufficient for the full suite

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What does mandatory ensemble shadow provenance failed mean

This message affected the V42 branch and was corrected for V44.

In short

An older release could report the morning run as failed even though a forecast was still available. The specific mandatory error is absent from the current V44 code.

Update SFML, STATS, and EAI together. If the message persists under V44, report it with full version and host context.

What to check

  • SFML is V44.0.0 or newer
  • Bundled STATS and EAI versions match
  • Home Assistant was restarted when requested
  • Do not confuse old log entries with current events
View updates

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What do EOD partial and individual timeouts mean

A skipped learning step does not necessarily mean data loss or a broken forecast.

In short

Assess the full routine instead of the most alarming log line. A result such as 15 of 16 may mean that no suitable data was available for an optional learning step that day. A bounded astronomy or database request can also be skipped safely.

Action is required when messages repeat for several days and forecasts, sensors, or freshness fail at the same time.

What to check

  • Read the result of the complete routine
  • Check forecast sensors and data freshness
  • Observe recurrence over several days
  • Capture the complete relevant log section if the issue persists

✓Technically reviewed: SFML · STATS · EAI V52.0.4

How do I check whether an issue is already fixed

Compare the installed component version, Home Assistant version, and current release notes first.

In short

Many reports concern older combinations. Record the version of every affected component and check whether release notes already list the issue as fixed. Treat SFML, STATS, and EAI as a coordinated version set.

What to check

  • Record versions in Home Assistant
  • Check HACS for pending updates
  • Compare installed and current release notes
  • Complete the requested restart
Open update history

✓Technically reviewed: SFML · STATS · EAI V52.0.4

How to ask a question that gets a quick answer

Describe what you expected, what happened instead, and the last change. A screenshot helps more than a log excerpt.

In short

Log messages are meant for development. They are hard to interpret from the outside, because large parts of the code are protected — a language model cannot interpret them reliably either and will invent an explanation when it is unsure. Something else gets you a faster answer: describe what you expected, what happened instead, since when, and what changed last. Name the version, the installation type, and the component involved. A screenshot of the place says more than an excerpt from the log.

What to check

  • What you expected
  • What happened instead
  • Since when, and what changed last
  • Version, installation type, and the component involved
  • A screenshot of the place
What information makes a useful bug report

✓Technically reviewed: SFML · STATS · EAI V52.0.4

What information makes a useful bug report

Version, host, timestamp, reproducible behaviour, and the connected relevant log section are essential.

In short

One red line is rarely enough for root-cause analysis. Describe what you expected, what happened, and when it started. Remove credentials, tokens, public IP addresses, names, and other personal information from logs and images.

What to check

  • Home Assistant and component versions
  • Host system and installation type
  • Timestamp and reproducible steps
  • Log section before and after the error
  • No secrets or personal information
Open bug tracker

✓Technically reviewed: SFML · STATS · EAI V52.0.4

Does my question belong in help or the issue area

Understanding and setup belong in help; confirmed defects are documented in the bug tracker and reproducible new cases are reported in the issue area.

In short

This help centre is authoritative. Community forums are independent exchange among users and not an official point of contact. Use this help centre for sensor selection, configuration, status questions, and interpreting results. Check the bug tracker for known or resolved cases. You can then report a reproducible defect in a current supported version in the issue area of the community forum.

A general AI assistant can help structure logs but cannot inspect protected SFML code and must not present a guessed root cause as confirmed.

What to check

  • Search help, bug tracker, and release notes first
  • Confirm the current version
  • Distinguish a question from a reproducible defect
  • Do not publish personal data or credentials
Check the bug trackerOpen the issue area in the community forum (external)

✓Technically reviewed: SFML · STATS · EAI V52.0.4

COMMUNITY

Your question is still open

This help centre is the authoritative source. For exchange with other users there are SFML areas in independent community forums; they do not belong to the project. Check a reproducible defect in the bug tracker first, then report it in the issue area with the version, host system, and the relevant log section.

Open the bug trackerOpen the SFML area in the community forum (external)